Date |
Text |
2018-02-12 17:02:20 | BUILDING PLAN REVIEW |
| W. P. B. REVISION: 17070136 |
| W. P. B. PERMIT: 15111020 |
| ADD: 1100 S. FLAGLER DR. |
| CONT: SUFFOLK CONSTRUCTION CO. |
| TEL: 561-832-1616 |
| E-MAIL: [email protected] / ED HANRATTY |
| 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| 3RD REVIEW |
| DATE: MON. FEB. 12/ 2018 |
| |
| ACTION: BUILDING PROVISO |
| |
| 1) PROVISO: SHAFT WALLS AND CHASE WALLS TO COMPLY WITH |
| 2010 FBC-B 1207.2 AIR-BORNE SOUND. WALLS, PARTITIONS |
| AND FLOOR/ CEILING SEPARATING DWELLING UNITS FROM EACH |
| OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A |
| SOUND TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45 |
| IF FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED IN |
| ACCORDANCE WITH ASTM E 90. |
| |
| 2) PROVISO: RESPONSE INDICATES THE ROOFING COMPOSITION |
| IS STILL PENDING TO BE PROVIDED AT A LATER TIME AS A |
| DEFERRED SUBMITTAL. 107.3.4.2. 2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION. |
| |
| 3)PROVISO: VOIDED FOR THIS REVIEW. FOLDER20171212 PDF |
| SHEET GENERATOR FRAMING ENCLOSURE, NO ELECTRONIC |
| SIGNATURE FROM ROBERT WARR. P. E. AND NEEDS / PROVIDE |
| SHAFTWALL INSTALLATION DETAILS. |
| 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING |
| ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, |
| REPORTS OR OTHER DOCUMENTS. |
| FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A |
| SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE |
| OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON |
| ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS, |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST./ WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 / FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |