2017-07-19 15:06:20 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PROVIDE LANDING AT EXTERIOR STAIRS PER FBC R311.7.6 |
| 2. HANDRAIL HEIGHT SHALL BE BETWEEN 34" AND 38" PER FBC |
| R311.7.8.1 |
| 3. GUARDS SHALL BE PER FBC R312.1.3 |
| |
| R311.7.6 LANDINGS FOR STAIRWAYS. |
| THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM |
| OF EACH STAIRWAY. THE MINIMUM WIDTH PERPENDICULAR TO |
| THE DIRECTION OF TRAVEL SHALL BE NO LESS THAN THE WIDTH |
| OF THE FLIGHT SERVED. LANDINGS OF SHAPES OTHER THAN |
| SQUARE OR RECTANGULAR SHALL BE PERMITTED PROVIDED THE |
| DEPTH AT THE WALK LINE AND THE TOTAL AREA IS NOT LESS |
| THAN THAT OF A QUARTER CIRCLE WITH A RADIUS EQUAL TO |
| THE REQUIRED LANDING WIDTH. WHERE THE STAIRWAY HAS A |
| STRAIGHT RUN, THE MINIMUM DEPTH IN THE DIRECTION OF |
| TRAVEL SHALL BE NOT LESS THAN 36 INCHES (914 MM). |
| |
| R311.7.8 HANDRAILS. |
| HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF |
| EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR |
| MORE RISERS. R311.7.8. |
| HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED |
| PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF |
| RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) |
| AND NOT MORE THAN 38 INCHES (965 MM). R311.7.8.1 HEIGHT |
| |
| R312 GUARDS |
| R312.1.3 OPENING LIMITATIONS. |
| REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE |
| WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH |
| ALLOW PASSAGE OF A SPHERE 4 INCHES (102 MM) IN |
| DIAMETER. |
| |
| |