2017-07-25 08:37:47 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| COMMENTS. |
| CODE: FBC 5TH EDITION (2014). |
| |
| 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT. |
| BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID |
| RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF |
| THE UNIFIED LAND DEVELOPMENT CODE. |
| |
| 2- THIS PROPERTY WAS SUBDIVIDED INTO TWO LOTS. LOT 11 |
| AND LOT 12. THIS PERMIT APPLICATION IS FOR THE HOUSE TO |
| BE BUILT IN LOT 12. THE PROPOSED ADDRESS FOR LOT 12 IS |
| 749 TALLAPOOSA STREET. REVISE ADDRESS ON PLANS TO |
| REFLECT THE CORRECT ADDRESS. 745 TALLAPOOSA STREET IS |
| FOR THE HOUSE TO BE BUILT IN LOT 11. REVISE AS |
| REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 3- PROVIDE SOIL TEST REPORT (2 COPIES) . SEC. R401.4 |
| FBC-RESIDENTIAL 5TH EDITION (2014). |
| |
| 4- PROVIDE DRAINAGE PLAN ( 2 COPIES) AS REQUIRED BY |
| SEC. R401.3 FBC -RESIDENTIAL. |
| |
| 5- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW. |
| VALUE TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S |
| OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS |
| REQUIRED BY SEC. 109.3 CITY AMENDMENTS. THE VALUATION |
| WAS UPDATED TO $192,501. THE PERMIT FEE BALANCE IS |
| $3,627.36. |
| |
| 6- SHEET 1-4: |
| A) THE LOADS SPECIFIED ON THE DESIGN CRITERIA DON'T |
| MATCH THE LOADS SPECIFIED ON STRUCTURAL NOTE #2 ON SAME |
| DRAWING. REVISE AS REQUIRED TO MATCH. ALSO, THE ATTIC |
| LIVE LOAD NEEDS TO BE REVISED IF THE ATTIC ACCESS HAS |
| AN STAIR AND FOOTNOTES "B" AND "G" OF TABLE R301.5 |
| FBC-RESIDENTIAL APPLY. |
| |
| B) SPECIFY ATTIC ACCESS SIZE. SEC. R807 |
| FBC-RESIDENTIAL. |
| |
| C) STRUCTURAL NOTE #2 REFERENCES FBC 2010. THE CURRENT |
| CODE IS FBC 5TH EDITION (2014). REVISE AS REQUIRED. |
| SEC. 553 F.S. |
| |
| 7- SHEET 3-4: FOUNDATION PLAN IDENTIFIES DETAIL |
| SECTIONS 1/S-3 AND 2/S-3. THERE IS NO S-3 SHEET. REVISE |
| AS REQUIRED. PROVIDE CORRECT DETAIL REFERENCE. . SEC. |
| 107.2.1 CITY AMENDMENTS. |
| |
| 8- PLANS NEED TO SPECIFY CARBON MONOXIDE ALARMS FOR ALL |
| BEDROOMS. SEE SEC. R315.1 FBC-RESIDENTIAL FOR REQUIRED |
| LOCATION. |
| |
| 9- ENERGY CALCULATIONS SUBMITTED: |
| A) OWNER OR LEGALLY DESIGNATED AGENT TO CERTIFY AND |
| DATE BOTTOM OF FORM AS REQUIRED BY SEC. R103.1.1.2 |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| B) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF |
| FORM. THE ADDRESS NEEDS TO BE COORDINATED WITH ITEM #2 |
| ABOVE. THE OWNER NAME DOESN'T MATCH OWNER INFORMATION |
| SHOWN ON THE PERMIT APPLICATION AND PBC PROPERTY |
| APPRAISER. REVISE AS REQUIRED TO MATCH. ALSO, PROVIDE |
| THE BUILDER'S NAME, PERMIT OFFICE AND JURISDICTION |
| NUMBER 604700. |
| SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| C) INSULATION R-VALUE SHOWN ON ITEM #9 DOESN'T MATCH |
| PLANS. REVISE AS REQUIRED TO MATCH. SEC. R103.2 |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| D) PAGE 3 OF 4 IS SHOWING AN ATTIC VENT RATIO OF 1/300. |
| TYPICALLY THE VENTILATION RATIO IS 1/150. PERSON |
| PREPARING THE ENERGY CALCULATIONS TO PROVIDE DETAILS |
| AND SPECIFICATIONS SHOWING COMPLIANCE WITH SEC. R806.2 |
| FBC-RESIDENTIAL TO GET THE 1/300 VENT RATIO. |
| |
| NOTE: |
| LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND |
| SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL |
| BE REQUIRED WHEN THE CALCULATIONS ARE NOT USING THE |
| SOFTWARE DEFAULT FACTOR FOR GLAZING. |
| |
| 10- ENGINEER PLANS NEED TO BE REVISED SHOWING THE |
| COMPLIANCE WITH THE 1/300 ATTIC VENT RATIO. COORDINATE |
| WITH ENERGY CALCULATIONS SUBMITTED. SEC. R103.2 |
| FBC-ENERGY CONSERVATION. |
| |
| 11- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.001 FOR: |
| A) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| |
| B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS |
| AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL |
| COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR |
| ENGINEER OF RECORD TO LIST THE FLORIDA PRODUCT APPROVAL |
| NUMBER NEXT TO EACH SPECIFIED CONNECTOR. |
| |
| ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD |
| DRAWIINGS FOR REFERENCE TO EXPEDITE THE REVIEW PROCESS. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |