Plan Review Notes For Permit 17061134 |
Permit Number |
17061134 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2017-07-06 06:35:21 | 1) SUBMIT MANUF. SPECIFICATIONS AND SOLAR CERTIFICATION | | FOR THE TANK IN THE GARAGE.WPB AMEND. TO FBC SEC. | | 107.2.1. | | 2) SHOW THE SIZE OF THE WATER LINES ON THE PLANS. | | SUBMIT A WATER RISER DIAGRAM SHOWING THE REQUIRED | | ISOLATION VALVES FOR THE COLLECTOR, THE PRESSURE AND | | TEMPERATURE RELIEF VALVE, VACUUM RELIEF VALVE, AND | | PROTECTION FROM FREEZING PER THE 2014 FBC-RES.. SECS. | | M2301.2.3, M2301.2.8. M2301.2.4 & M2301.2.5. | | 3) SHOW THE REQUIRED EXPANSION TANK FOR THE SYSTEM PER | | 2014 FBC-RES. SEC.M2301.2.6.THE TANK SHALL BE SIZED IN | | ACCORDANCE WITH SEC.M2003. | | 4) PROVIDE INFORMATION ON THE MAXIMUM TEMPERATURE | | LIMITATION REQUIRED FOR THE HOT WATER PER 2014 FBC-RES. | | SEC.M2301.2.9. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|