2017-09-14 18:07:58 | REVIEW COMMENTS |
| |
| 3RD REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) (PREVIOUS COMMENT) SPECIFY THE DESIGN DATA ON THE |
| PLANS. PROVIDE THE APPLICABLE CODES, OCCUPANCY TYPE AND |
| TYPE OF CONSTRUCTION. FBC-R301 ( THIS IS AN R-3 |
| OCCUPANCY TYPE AND TYPE VB CONSTRUCTION. ) |
| |
| 2) (PREVIOUS COMMENT) FBC-R314.3.1 ALTERATIONS, REPAIRS |
| AND ADDITIONS. WHEN ALTERATIONS, REPAIRS OR ADDITIONS |
| REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING |
| ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE |
| INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE |
| ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. SHOW THE |
| SMOKE ALARMS ON THE PLANS. |
| |
| 3) (PREVIOUS COMMENT)THE PROPOSED FAMILY ROOM THAT IS |
| SHOWN ON THE PLANS IS CURRENTLY A SCREENED PORCH. THE |
| INSTALLATION OF THE SLIDING GLASS DOORS AT THE EXTERIOR |
| OF THE SCREEN PORCH ( UNDER PERMIT # 17060843 ) AND THE |
| PROPOSED REMOVAL OF THE DOORS BETWEEN THE PORCH AND THE |
| EXISTING LIVING SPACE WILL CONVERT THE PORCH TO |
| CONDITIONED SPACE. FBC ENERGY CONSERVATION SECTION |
| R101.4.5 REQUIRES ANY UNCONDITIONED SPACE THAT IS |
| ALTERED TO BECOME CONDITIONED SPACE TO BE BROUGHT INTO |
| FULL COMPLIANCE WITH THE ENERGY CODE. SUBMIT TWO SETS |
| OF FORMS AND DOCUMENTS TO SHOW COMPLIANCE. FBC ENERGY |
| CONSERVATION SECTION R103. |
| |
| 4) THIS STRUCTURE IS LOCATED IN EXPOSURE C AND THE |
| PLANS INDICATE THAT IT IS LOCATED IN EXPOSURE CATEGORY |
| B. PLEASE CORRECT. FBC-R301.2.1.4.3 |
| |
| |