2017-07-24 07:28:01 | REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) SPECIFY THE DESIGN DATA ON THE PLANS. PROVIDE THE |
| APPLICABLE CODES, OCCUPANCY TYPE AND TYPE OF |
| CONSTRUCTION. FBC-R301 |
| |
| 2) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. |
| ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND |
| ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF |
| THE PERSON RESPONSIBLE FOR THE DESIGN. |
| |
| 3) FBC-R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. |
| WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A |
| PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE |
| ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| LOCATED AS REQUIRED FOR NEW DWELLINGS. |
| |
| 4) PROVIDE A DETAIL SHOWING HOW THE MASTER BEDROOM WALL |
| WILL BE FILLED IN WHEN THE SLIDING GLASS DOOR IS |
| REMOVED. FBC-R601 |
| |
| 5) THE PROPOSED FAMILY ROOM THAT IS SHOWN ON THE PLANS |
| IS CURRENTLY A SCREENED PORCH. THE INSTALLATION OF THE |
| SLIDING GLASS DOORS AT THE EXTERIOR OF THE SCREEN PORCH |
| ( UNDER PERMIT # 17060843 ) AND THE PROPOSED REMOVAL OF |
| THE DOORS BETWEEN THE PORCH AND THE EXISTING LIVING |
| SPACE WILL CONVERT THE PORCH TO CONDITIONED SPACE. FBC |
| ENERGY CONSERVATION SECTION R101.4.5 REQUIRES ANY |
| UNCONDITIONED SPACE THAT IS ALTERED TO BECOME |
| CONDITIONED SPACE TO BE BROUGHT INTO FULL COMPLIANCE |
| WITH THE ENERGY CODE. SUBMIT TWO SETS OF FORMS AND |
| DOCUMENTS TO SHOW COMPLIANCE. FBC ENERGY CONSERVATION |
| SECTION R103. |
| |
| 6) SHOW THE EXTERIOR WALL AND CEILING INSULATION FOR |
| THE ENCLOSED PORCH ( PROPOSED FAMILY ROOM ) ON THE |
| PLANS. FBC ENERGY CONSERVATION SECTION 402. |
| |
| 7) THE PLANS INDICATE THAT PREVIOUSLY UNCONDITIONED |
| SPACE IS BEING CONVERTED TO HABITABLE SPACE. PROVIDE |
| AREA TABULATIONS ON THE PLANS TO SHOW THE SQUARE |
| FOOTAGE OF EXISTING AND PROPOSED CONDITIONED AND |
| UNCONDITIONED AREAS. FBC 107.2.1 |
| |
| 8) THE PLANS ARE REQUIRED TO BE REVIEWED BY PALM BEACH |
| COUNTY FOR IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT |
| CAN BE ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH |
| COUNTY. UPON APPROVAL, ONE SET OF PLANS SHALL BE SIGNED |
| OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN IMPACT |
| FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP AND A |
| COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE CITY |
| BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN BE |
| ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY IMPACT |
| FEES AT (561) 233-5025. |
| |
| 9) THE VALUATION FOR THIS WORK APPEARS TO BE LOW. |
| SUBMIT A COPY OF THE SIGNED CONTRACT. FBC 109.3 |
| BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, |
| PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE |
| WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, |
| OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| |
| 10) THE PLANS THAT WERE SUBMITTED DO NOT SHOW THE |
| REQUIRED EGRESS WINDOW FOR BEDROOM #2. CLARIFY. FBC - |
| R310 |
| |
| 11) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT |
| A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| COMMENTS HAS BEEN ADDRESSED. |
| |