Plan Review Notes
Plan Review Notes For Permit 17060851
Permit Number 17060851
Review Stop P
Sequence Number 1
Notes
Date Text
2017-07-12 17:10:571ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. 7.1 PLEASE SHOW THE WATER CLOSET IN THE POWDER
 ROOM BATH CONNECTING TO THE BRANCH DRAIN TO LAV IT IS
 SHOWN ON THE BUILDING DRAIN NOW. PER FBC RES P3108.1
  
 2. THE TWOWAY CLEAN OUT AT THE BUILDING DRAIN AND
 BUILDING SEWER JUNCTION SHALL BE 4". PER FBC RES
 P3005.2.9
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  