2017-06-24 08:00:21 | 2014 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17060837 |
| ADD: 321 15TH STREET, SUITE 100 |
| CONT: BUTLER CONSTRUCTION |
| TEL: 561-832-9700 |
| E-MAIL: SBUTLER@BUTLERCONSTRUCTION USA.COM |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: SAT. JUNE 24/ 2017 |
| ACTION: DENIED |
| |
| 1) LIFE SAFETY SHEET LS-1.1: |
| 1A) THE LIFE SAFETY REQUIREMENTS LIST 100 FT. COMMON |
| PATH OF TRAVEL. PLEASE BE ADVISED THIS BUILDING IS |
| UNSPRINKLERED AND THIS TENANT SPACE HAS AN OCCUPANT |
| LOAD OF 31. THE 2014 FBC-B TABLE 1014.3 LIMITS THE |
| TRAVEL DISTANCE IN UNSPRINKLERED BUILDINGS WITH |
| OCCUPANT LOADS OF 30 OR MORE TO 75 FEET. |
| |
| 1B) LIFE SAFETY CALCULATIONS ALSO INDICATE THE COMMON |
| PATH OF TRAVEL IS 100 FT. PLEASE CORRECT FOR BUILDINGS |
| THAT ARE UNSPRINKLERED AND AN OCCUPANT LOAD OF 30 OR |
| MORE THE COMMON PATH OF TRAVEL IS 75 FEET. REVIEW THE |
| 2014 FBC-B TABLE 1014.3. |
| |
| 1C) LIFE SAFETY CALCULATIONS ALSO INDICATE THE REQUIRED |
| NUMBER OF EXITS IS ONE. SINCE THE PLANS INDICATE THE |
| COMMON PATH OF TRAVEL IS 93 FEET, THE COMMON PATH OF |
| TRAVEL IS EXCEEDED, REQUIRING (2) MEANS OF EGRESS. 2014 |
| FBC-B 1015.1 (2) THE COMMON PATH OF TRAVEL EXCEEDS ONE |
| OF THE LIMITATIONS OF SECTION 1014.3. |
| |
| 1D) SHEET LS-1.1, WITHIN THE TENANT SPACE THERE IS A |
| SECOND EXIT ACCESS DOORWAY THAT LEADS INTO A VERTICAL |
| EXIT STAIRWELL. PLEASE PROVIDE THE CONTINUATION OF THE |
| EXIT, OR EXIT PASSAGEWAY SEE1021.3. EXIT CONFIGURATION, |
| OR IS THE STAIRWAY AN EXIT ACCESS STAIRWAY, IF SO |
| PROVIDE THE TRAVEL DISTANCE MEASUREMENTS IN ACCORDANCE |
| WITH 1016.3.1. |
| |
| 1E) PLEASE PROVIDE THE FIRE RATING OF THE EXIT ACCESS/ |
| EXIT DOOR OF THE INTERIOR STAIRWELL. 2014 FBC-B TABLE |
| 716.5. |
| |
| 1F) FOR THE 2ND MEANS OF EGRESS FROM THE TENANT SPACE |
| ONE HAS TO TRAVEL THROUGH THE STAIRWELL AND INTO A WIDE |
| CORRIDOR, PLEASE IDENTIFY THE VARIOUS OBJECT LOCATED |
| WITHIN AREA/ 107.2.1.3 ADDITIONAL INFORMATION IS |
| REQUIRED. |
| |
| 2) SHEET A-1.2 CEILING PLAN IS MISSING THE EXIT LIGHT |
| FOR THE SECOND MEANS OF EGRESS. 1011.1 WHERE REQUIRED & |
| 1011.3 ILLUMINATION. |
| |
| 3A) SHEET A-2.0 DETAIL (A) CRITICAL DIMENSIONS, DOES |
| NOT PROVIDE FOR SIGNAGE, FBC-B 1011.4 RAISED CHARACTER |
| AND BRAILLE EXIT SIGNS. |
| |
| 3B) SHEET A-2.0 DETAIL (A) CRITICAL DIMENSIONS, PLEASE |
| ALSO PROVIDE COMPLIANCE WITH 2014 FBC-ACCESSIBILITY |
| CODE SECTION 703.4.1 HEIGHT ABOVE FINISH FLOOR OR |
| GROUND. |
| TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES |
| (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND |
| SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST |
| TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE |
| THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE |
| BASELINE OF THE HIGHEST TACTILE CHARACTER. |
| |
| 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |