2017-07-19 17:01:45 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. SEPERATE PERMIT REQUIRED FOR DETACHED GARAGE. |
| SEPERATE PLANS NOT REQUIRED. THE FOLLOWING COMMENTS ARE |
| FOR THE MAIN RESIDENCE ONLY. |
| 2. IMPACT FEES REQUIRED. |
| 3. PROVIDE SITE DRAINAGE PLAN. |
| 4. DESIGN CRITERIA ON PLAN PAGE 2 OF 7 REFERENCES THE |
| 2010 FBC. CURRENT CODE IS 2014 FBC 5TH ED. |
| 5. PROVIDE SHOP DRAWINGS, SIGNED AND SEALED BY DESIGN |
| PROFESSIONAL FOR PRE-ENGINEERED CONCRETE FLOOR SYSTEM. |
| 6. PROVIDE ICC-ES REPORT (ESR-1826) FOR PROPOSED |
| ICYNENE INSULATION. DESIGNER TO SELECT SYSTEM TO BE |
| USED. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTION |
| ON-SITE AT TIME OF INSPECTION. |
| |
| BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT |
| FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. |
| UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE |
| SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN |
| IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP |
| AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE |
| CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN |
| BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY |
| IMPACT FEES AT (561) 233-5025. |
| |
| FBC-110.7 IMPACT OF CONSTRUCTION. NEW CONSTRUCTION |
| ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC |
| SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT |
| PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN |
| COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE |
| POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. |
| SUPPLY A DRAINAGE DESIGN |
| |
| GOVERNING CODES |
| 2014 FLORIDA BUILDING CODE 5TH ED W/2010 WEST PALM |
| BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER |
| 1 ADMINISTRATION |
| |
| R402.1.1 INSULATION AND FENESTRATION CRITERIA. |
| THE BUILDING THERMAL ENVELOPE SHALL MEET THE |
| REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE |
| ZONE SPECIFIED IN CHAPTER 3. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| REVIEWED SHEETS DETACHED AND MARK VOID. |
| |