Date |
Text |
2017-06-02 16:54:24 | 2014 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17051004 |
| ADD: 777 S FLAGLER DR. 14 TH FLOOR CORRIDOR |
| CONT: BUTLER CONSTRUCTION CO. |
| TEL: 561-832-9700 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. JUNE 02/ 2017 |
| ACTION: DENIED |
| |
| 1) PLEASE SEE THE PERMIT APPLICATION INDICATES UNDER |
| THE SCOPE OF WORK PARTIAL HALLWAY RENOVATION. SHEET |
| 002_ALS1.1 THE LIFE SAFETY PLAN CLASSIFIES THIS AS A |
| LEVEL 1 ALTERATION. SEE 2014 FBC-EXISTING BUILDING CODE |
| SECTION 503.1. LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL |
| AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, |
| ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, |
| ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME |
| PURPOSE. |
| THE LIFE SAFETY PLAN SHOWS NEW TENANT SEPARATION WALLS, |
| NOTE 9, NOTE 1 ALIGN NEW WALLS, WALL LEGEND SHOWS NEW 1 |
| HOUR RATED TENANT DISMISSING WALL AS WELL AS CORRIDOR |
| WALLS AND NOTE # 2 INDICATES NEW DOORS. |
| THIS IS A LEVEL II ALTERATION PLEASE CORRECT PLANS. |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| 2) THE NEWLY FORMED TENANT SPACE ON THE LEFT SIDE OF |
| THE PLANS PLEASE PROVIDE THE SQ. FEET OF THIS UNIT. |
| PLEASE ALSO PROVIDE THE OVERALL DIAGONAL DISTANCE FOR |
| THIS SPACE. DEPENDING ON THE SQ. FOOTAGE OF THE SPACE |
| AND OCCUPANT LOAD 2 MEANS OF EGRESS MAYBE REQUIRED. |
| THERE DISTANCE APART MAYBE REQUIRED TO BE 1/3RD THE |
| OVER ALL DIAGONAL DISTANCE APART. |
| 2014 FBC-B TABLE 1015.1. |
| 2014 FBC-B 1015.2.1. |
| |
| 3) THE 002_ ALS1.1 SHEET AND A1.1.1 SHOW A NEW DOOR |
| C1402 WITH SIDE LIGHTS, BUT 007_A2.0.1 DOOR C1402 IS |
| DOOR TYPE A, NO SIDELIGHTS ARE SHOWN. DISCREPANCY IN |
| PLANS. 107.2.1.3. PLEASE PROVIDE ADDITIONAL |
| INFORMATION. SHEET 008_A3.0.1. SHOW A DOOR # 1 WITH |
| DOUBLE DOORS AND SIDELIGHTS. |
| |
| 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |