2017-06-12 16:01:34 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. FEMA BULLETIN 1-98 AND SECTION 44 CODE OF FEDERAL | | REGULATIONS 60.3(B)(4) REQUIRE THAT COMMUNITIES | | "OBTAIN, REVIEW AND REASONABLY UTILIZE ANY BASE FLOOD | | ELEVATION AND FLOODWAY DATA AVAILABLE FROM A FEDERAL, | | STATE, OR OTHER SOURCE." | | | | THE FLOOD INSURANCE STUDY SHOWS THE FOLLOWING ON PAGE | | 47 OF THE FIS: | | | | WAVE CREST OF 8.0 NAVD88 AT TRANSECT 9, LOCATED ON THE | | SHORELINE OF LAKE WORTH IN THE CITY OF RIVIERA BEACH, | | CROSSING AVENUE B AT WEST 20TH STREET | | | | WAVE CREST OF 7.5 NAVD88 AT TRANSECT 10, LOCATED ON THE | | SHORELINE OF LAKE WORTH IN THE CITY OF WEST PALM BEACH, | | BETWEEN 23RD STREET AND PICCADILLY STREET | | | | THE MAP SHOWS A 7' BFE ON THE EAST SIDE OF THE PARCEL, | | BUT PLEASE NOTE THAT THE FIS IS TO BE USED AS THE MAP | | USES ROUNDING. | | | | THE SUBJECT PARCEL IS LOCATED BETWEEN THESE TWO | | TRANSECTS; DESIGNER MAY INTERPOLATE. PLEASE BE ADVISED | | THAT AS OF OCTOBER 5, 2017 THE FREEBOARD WILL LIKELY BE | | 2'; IT IS RECOMMENDED THAT THIS STRUCTURE BE DESIGNED | | WITH A 2' FREEBOARD. | | | | PLEASE CONTACT YOUR INSURANCE AGENT TO DISCUSS EFFECT | | ON RATES. | | | | PLEASE FEEL FREE TO CONTACT ME TO DISCUSS. | | | | | | | | |
|