Date |
Text |
2017-05-23 17:06:53 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. IDENTIFY LOCATION OF ALL FENCING ON SURVEY. |
| 2. THIS IS A POOL BARRIER, FENCE AND GATES SHALL COMPLY |
| WITH THE FOLLOWING: |
| R4502.17.1 OUTDOOR SWIMMING POOLS. |
| OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER |
| COMPLYING WITH SECTIONS R4501.17.1.1 THROUGH |
| R4501.17.1.14. |
| |
| R4501.17.1.1 |
| THE TOP OF THE BARRIER SHALL BE AT LEAST 48 INCHES |
| (1219 MM) ABOVE GRADE, MEASURED ON THE SIDE OF THE |
| BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. THE |
| MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM |
| OF THE BARRIER SHALL BE 2 INCHES (51 MM) MEASURED ON |
| THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE |
| SWIMMING POOL. WHERE THE TOP OF THE POOL STRUCTURE IS |
| ABOVE GRADE, THE BARRIER MAY BE AT GROUND LEVEL OR |
| MOUNTED ON TOP OF THE POOL STRUCTURE. WHERE THE BARRIER |
| IS MOUNTED ON TOP OF THE POOL STRUCTURE, THE MAXIMUM |
| VERTICAL CLEARANCE BETWEEN THE TOP OF THE POOL |
| STRUCTURE AND THE BOTTOM OF THE BARRIER SHALL BE 4 |
| INCHES (102 MM). |
| |
| R4501.17.1.2 |
| THE BARRIER MAY NOT HAVE ANY GAPS, OPENINGS, |
| INDENTATIONS, PROTRUSIONS, OR STRUCTURAL COMPONENTS |
| THAT COULD ALLOW A YOUNG CHILD TO CRAWL UNDER, SQUEEZE |
| THROUGH, OR CLIMB OVER THE BARRIER AS HEREIN DESCRIBED |
| BELOW. ONE END OF A REMOVABLE CHILD BARRIER SHALL NOT |
| BE REMOVABLE WITHOUT THE AID OF TOOLS. OPENINGS IN ANY |
| BARRIER SHALL NOT ALLOW PASSAGE OF A 4-INCH-DIAMETER |
| (102 MM) SPHERE. |
| |
| R4501.17.1.3 |
| SOLID BARRIERS WHICH DO NOT HAVE OPENINGS SHALL NOT |
| CONTAIN INDENTATIONS OR PROTRUSIONS EXCEPT FOR NORMAL |
| CONSTRUCTION TOLERANCES AND TOOLED MASONRY JOINTS. |
| |
| R4501.17.1.4 |
| WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND |
| VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF |
| THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES (1143 |
| MM), THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE |
| SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN |
| VERTICAL MEMBERS SHALL NOT EXCEED 1 3/4 INCHES (44 MM) |
| IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN |
| VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT |
| EXCEED 1 3/4 INCHES (44 MM) IN WIDTH. |
| |
| R4501.17.1.5 |
| WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND |
| VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF |
| THE HORIZONTAL MEMBERS IS 45 INCHES (1143 MM) OR MORE, |
| SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 4 |
| INCHES (102 MM). WHERE THERE ARE DECORATIVE CUTOUTS |
| WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS |
| SHALL NOT EXCEED 1 3/4 INCHES (44 MM) IN WIDTH. |
| |
| R4501.17.1.6 |
| MAXIMUM MESH SIZE FOR CHAIN LINK FENCES SHALL BE A 21/4 |
| INCH SQUARE (57 MM) UNLESS THE FENCE IS PROVIDED WITH |
| SLATS FASTENED AT THE TOP OR BOTTOM WHICH REDUCE THE |
| OPENINGS TO NO MORE THAN 1 3/4 INCHES (44 MM). |
| |
| R4501.17.1.7 |
| WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS, THE |
| MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS SHALL BE |
| NO MORE THAN 13/4 INCHES (44 MM). |
| |
| R4501.17.1.8 |
| ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND |
| SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS |
| R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED |
| WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL |
| SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED |
| NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE |
| GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON |
| EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE |
| REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY |
| OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE |
| ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM |
| THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING |
| GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457 |
| MM) OF THE RELEASE MECHANISM. |
| |