Date |
Text |
2017-07-24 15:42:36 | 7/24/2017 RAMP SUBMITTED UNDER PERMIT 17070240 PASSED |
| BY C. TROOP MAKING A ACCESSIBLE FRONT ENTRY AND SAME |
| PATH TO THE RECEPTIONIST. JW. |
2017-07-14 06:44:13 | 2014 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17040865 |
| ADD: 101 N. CLEMATIS ST. SUITE: 110 |
| CONT: TBD TO BE DETERMINED |
| TEL: [email protected] |
| E-MAIL: 954-914-9848 |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: FRI. JULY 14/ 2017 |
| ACTION: DENIED. |
| |
| 1E) REQUESTED AS A DEFERRED SUBMITTAL. SHEET A-110.00 |
| SHOWS A PROPOSED NEW ACCESSIBLE RAMP LOCATION THAT WILL |
| SATISFY BOTH COMMENTS 1E & COMMENT 2. THIS RAMP |
| LOCATION WILL ALSO NEED ZONING APPROVAL. THE DESIGNER |
| OF RECORD HAS NOT MET THE ZONING REQUIREMENT THAT THE |
| RAMP HAS NOT MET THE MINIMUM 16 FOOT SETBACK AS |
| MEASURED FROM THE BACK OF THE EXISTING CURB ALONG |
| CLEMATIS ST. |
| |
| 1F) PLEASE NOTE THE PROPOSED RAMP DESIGN WILL NEED TO |
| SHOW COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE |
| 405.7.4 CHANGE IN DIRECTION. |
| 405.7.4 CHANGE IN DIRECTION. RAMPS THAT CHANGE |
| DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR |
| LANDING 60 INCHES (1525 MM) MINIMUM BY 60 INCHES (1525 |
| MM) MINIMUM. |
| |
| 1ST ROUND OF COMMENTS. EGRESS REQUIREMENTS INDICATE (2) |
| ARE REQUIRED AND 4 ARE PROVIDED. IN THE SCOPING |
| REQUIREMENTS CHAPTER 2 OF THE ACCESS. CODE SECTION |
| 206.4.1. PUBLIC ENTRANCES. IN ADDITION TO ENTRANCES |
| REQUIRED BY 206.4.2 THROUGH 206.4.9, AT LEAST 60 |
| PERCENT OF ALL PUBLIC ENTRANCES SHALL COMPLY WITH 404. |
| BARRIERS AT COMMON OR EMERGENCY ENTRANCES AND EXITS OF |
| BUSINESS ESTABLISHMENTS CONDUCTING BUSINESS WITH THE |
| GENERAL PUBLIC THAT ARE EXISTING, UNDER CONSTRUCTION, |
| OR UNDER CONTRACT FOR CONSTRUCTION WHICH WOULD PREVENT |
| A PERSON FROM USING SUCH ENTRANCES OR EXITS SHALL BE |
| REMOVED. PLEASE NOTE IN SPEAKING WITH THE BUILDING |
| OFFICIAL WE ARE CONSIDERING THE FRONT ENTRY DOORS AS |
| ONE ENTRANCE, 3 X 0.6 = 1.8 OR (2) ACCESSIBLE MEANS OF |
| EGRESS ARE REQUIRED, PLEASE SHOW ON THE PLANS . |
| |
| 2) NOT SATISFIED UNTIL COMMENT (1E) IS SATISFIED. SHEET |
| A-110.00 PLEASE REVIEW THE LAYOUT OF THE FRONT ENTRY, |
| RECEPTION AND WAITING AREAS AND SHOW HOW COMPLIANCE |
| WITH SECTION 206.3 OF THE ACCESS. CODE IS TO BE |
| COMPLIED WITH. 206.3 LOCATION. |
| ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN |
| THE SAME AREA AS GENERAL CIRCULATION PATHS. WHERE |
| CIRCULATION PATHS ARE INTERIOR, REQUIRED ACCESSIBLE |
| ROUTES SHALL ALSO BE INTERIOR. |
| ADVISORY 206.3 LOCATION. THE ACCESSIBLE ROUTE MUST BE |
| IN THE SAME AREA AS THE GENERAL CIRCULATION PATH. THIS |
| MEANS THAT CIRCULATION PATHS, SUCH AS VEHICULAR WAYS |
| DESIGNED FOR PEDESTRIAN TRAFFIC, WALKS, AND UNPAVED |
| PATHS THAT ARE DESIGNED TO BE ROUTINELY USED BY |
| PEDESTRIANS MUST BE ACCESSIBLE OR HAVE AN ACCESSIBLE |
| ROUTE NEARBY. ADDITIONALLY, ACCESSIBLE VERTICAL |
| INTERIOR CIRCULATION MUST BE IN THE SAME AREA AS STAIRS |
| AND ESCALATORS, NOT ISOLATED IN THE BACK OF THE |
| FACILITY. |
| |
| 3) COMPLIED. |
| |
| 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |
| |
| |