Date |
Text |
2017-09-27 12:40:55 | 2014 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17040199 |
| ADD: 1515 N. FLAGLER DR. SUITE 100 & 700 |
| CONT: LB DEVELOPMENT & ENGINEERING |
| TEL: 954-881-5693 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 5TH REVIEW |
| DATE: WED. SEPT. 27/ 2017 |
| ACTION: BUILDING PROVISO |
| |
| 1A) SHEET A4.23 DETAIL 1 THE AMBULATORY ACCESSIBLE |
| COMPARTMENT DOOR WILL NEED TO SHOW COMPLIANCE WITH 2014 |
| FBC-ACCESSIBILITY CODE 604.8.2.2 DOORS. TOILET |
| COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL |
| COMPLY WITH 404, EXCEPT THAT IF THE APPROACH IS TO THE |
| LATCH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN |
| THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION |
| SHALL BE 42 INCHES MINIMUM. THE DOOR SHALL BE |
| SELF-CLOSING. A DOOR PULL COMPLYING WITH 404.2.7 SHALL |
| BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. |
| |
| 1B) 2014 ACCESSIBILITY CODE 404.2.3 CLEAR WIDTH. DOOR |
| OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES |
| MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS |
| SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE |
| STOP, WITH THE DOOR OPEN 90 DEGREES. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |