 PLUMBING COMMENTS:
  
 1. PROVIDE RISER DIAGRAM FOR NEW WASHING MACHINE . PER
 WPB AMEND TO FBC 107.3.5.1.3(13)
  
 2. WASHING MACHINE BRANCH DRAIN SHALL BE MIN OF 3" PER
 FBC PL 406.2
  
 3. THE WASHING MACHINE DRAIN SHALL NOT TIE INTO THE WET
 VENT OF THE BATHROOM GROUP, IT SHALL TIE IN DOWN STREAM
 OF BATHROOM GROUP. PER FBC PL 912.1
  
  
  
 FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT
 THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL
 COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  