2017-03-22 07:48:36 | W. P. B. BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17030831 |
| ADD: 735 HANSEN ST. |
| CONT: ROOFING SYSTEMS OF FLORIDA, INC. |
| TEL: 561-308-3000 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: WED. MARCH 22/2017 |
| ACTION: DENIED |
| |
| 1) THE PERMIT APPLICATION DOES NOT INDICATE THE TYPE OF |
| ROOFS TO BE REROOFED. THE COUNTYWIDE GIS SYSTEM SHOWS |
| THE PROPERTY OF 735 HANSEN TO HAVE A GABLE ROOF WITH |
| SHINGLES AND A FLAT SECTION OF ROOF AS WELL. IT IS |
| ASSUMED THAT BOTH THE GABLED SHINGLE SECTION OF ROOF |
| AND THE FLAT ROOF BOTH ARE TO BE REROOFED. WITH THAT |
| BEING SAID THE PRODUCT APPROVAL SUBMITTED FOR THE FLAT |
| ROOF A CERTAIN TEED MODIFIED BITUMEN ROOFING SYSTEM, |
| NOA 14-0529.02 PAGE 27 SHOWS SYSTEM TYPE E7 A BASE |
| SHEET MECHANICALLY FASTENED WITH A MAXIMUM DESIGN |
| PRESSURE OF -60 PSF AND GENERAL LIMITATION # 7. FOR A |
| EXPOSURE C AT 15 FEET IN ZONE # 2 THE NEGATIVE PRESSURE |
| IS -63.6 AND ZONE # 3 THE PRESSURE IS -95.7. LIMITATION |
| # 7 IS IN AFFECT. REVIEW THE PRODUCT APPROVAL |
| LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF |
| ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR |
| BOTH INSULATION & THE BASE SHEET AS CALCULATED IN |
| COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. |
| CALCULATION PREPARED, SIGNED AND SEALED BY A FLORIDA |
| REGISTERED PROFESSIONAL ENGINEER OR REGISTERED |
| ARCHITECT. FBC-R 301.2(3). |
| |
| 2) PLEASE ALSO PROVIDE THE SLOPE OF THE ROOF FOR THE |
| SHINGLE PORTION OF THE ROOF. ROOFING ASPHALT SHINGLES |
| 2014< 4/12 PITCH. R905.2.7 UNDERLAYMENT APPLICATION. |
| UNDERLAYMENT SHALL BE INSTALLED USING ONE OF THE |
| FOLLOWING METHODS: |
| FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS |
| HORIZONTAL (17-PERCENT SLOPE), AND LESS THAN FOUR UNITS |
| VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE). |
| UNDERLAYMENT SHALL COMPLY WITH ASTM D 226, TYPE I OR |
| TYPE II OR ASTM D 4869, TYPE II OR TYPE IV OR ASTM D |
| 6757 AND SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING |
| MANNER. APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT |
| FELT PARALLEL TO AND STARTING AT THE EAVES, FASTENED |
| SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, |
| APPLY |
| 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT, |
| OVERLAPPING SUCCESSIVE SHEETS 19 INCHES. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| DEVELOPMENT SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |
| |
| |
| |
| |
| |
| |