2017-02-10 03:10:54 | 1) IS THE NEW TANKLESS WATER HEATER REPLACING AN |
| EXISTING TANKLESS WATER HEATER OR IS THE TANKLESS |
| REPLACING A TANK TYPE WATER HEATER? NOTE THIS ON THE |
| PLAN.IF A TANK TYPE WATER HEATER IS BEING REPLACED WITH |
| THE TANKLESS, AN UPGRADE TO THE ELECTRIC MAY BE |
| REQUIRED WHICH WILL REQUIRE A SEPARATE PERMIT. WPB |
| AMEND. TO FBC SEC.107.2.1. |
| 2) IS THE TANKLESS WATER HEATER BEING INSTALLED ON THE |
| INTERIOR OR EXTERIOR OF THE STRUCTURE? SUBMIT TWO |
| COPIES OF A HOUSE PLAN SHOWING THE LOCATION OF THE |
| TANKLESS WATER HEATER AND THE LOCATION OF ANY OPERABLE |
| DOORS OR WINDOWS. THE LOCATION OF THE WATER HEATER |
| SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION |
| INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND DRAWN. WPB |
| AMEND. TO FBC SEC. 107.2.1. |
| 3) SUBMIT 2 COPIES OF THE MANUFACTURER'S |
| SPECIFICATIONS/INSTALLATION INSTRUCTIONS FOR THE |
| TANKLESS WATER HEATER. WPB AMEND. TO FBC SECS. |
| 102.1,107.2.1. |
| 4) CLEARLY IDENTIFY ON THE SANITARY RISER DIAGRAM WHAT |
| PIPING IS BEING REPLACED. IS ALL THE UNDERGROUND/UNDER |
| SLAB PIPING BEING REPLACED INCLUDING THE STACKS? |
| 5) IF THE AREA UNDER THE SLAB IS TO BE TUNNELLED TO |
| GAIN ACCESS TO THE EXISTING SANITARY LINES, THEN THE |
| FOLLOWING SHALL BE ADHERED TO: |
| |
| PLUMBING REPAIR TUNNEL WORK |
| |
| A CLEAR AND LEGIBLE SANITARY RISER DIAGRAM SHALL BE |
| SUBMITTED SHOWING ALL PIPE SIZES, CONNECTION POINTS TO |
| EXISTING PIPING, HOW THE NEW PIPE WILL BE SUPPORTED, |
| THE TYPE OF ADAPTERS USED FOR THE CONNECTIONS TO |
| EXISTING PIPE, AND THE LOCATIONS OF REQUIRED CLEANOUTS. |
| DETAILS AND BACKFILLING PROCEDURES SHALL BE SUBMITTED |
| THAT CLEARLY SHOW HOW THE STRUCTURAL INTEGRITY OF THE |
| CONCRETE SLAB WILL BE MAINTAINED DURING EXCAVATION AND |
| BACKFILLING. STRUCTURAL FOAM IS NOT PERMITTED BELOW |
| GROUND PER THE FLORIDA BUILDING CODE, RESIDENTIAL, |
| SECTION 318 AND THE FLORIDA BUILDING CODE, BUILDING, |
| SECTION 26. A SIGNED AND SEALED LETTER FROM AN ENGINEER |
| SHALL BE SUBMITTED FOR FINAL INSPECTION STATING THAT |
| THE STRUCTURAL INTEGRITY OF THE EXISTING SLAB HAS NOT |
| BEEN COMPROMISED. |
| |