2017-03-13 18:52:05 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS |
| SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING |
| OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| OF THE PERSON RESPONSIBLE FOR THE DESIGN. |
| |
| 2) FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING |
| PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. |
| THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, |
| SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO |
| RECORDS MANAGEMENT. |
| |
| 3) THE PLANS THAT WERE SUBMITTED ARE FROM A FLORIDA |
| LICENSED ARCHITECT AND ARE STAMPED "NOT FOR PERMIT". |
| ALL DOCUMENTS PREPARED AND SUBMITTED FOR PERMIT FROM AN |
| ARCHITECT ARE REQUIRED TO BE SIGNED AND SEAL BY THAT |
| ARCHITECT. FLORIDA STATUTES 481 & FLORIDA |
| ADMINISTRATIVE CODE 61G. |
| |
| 4) SUBMIT TWO SETS OF STRUCTURAL PLANS. FBC 107.3.5.3 |
| |
| 5) FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS AND |
| COMPONENT AND CLADDING DESIGN PRESSURES PURSUANT TO |
| FBC-R301.2. |
| |
| 6) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC |
| 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE |
| BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER |
| OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH |
| FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS |
| AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT |
| ROOFING MATERIALS, WINDOW/GLASS TYPES, STRUCTURAL |
| MULLIONS AND EXTERIOR DOOR TYPES. |
| |
| 7) FBC 107.3.5.3 ? INDICATE THE MEANS OF TERMITE |
| PROTECTION PROPOSED PURSUANT TO FBC-R318. |
| |
| 8) R401.3 DRAINAGE. SURFACE DRAINAGE SHALL BE DIVERTED |
| TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF |
| COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE |
| GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION |
| WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES (152 |
| MM) WITHIN THE FIRST 10 FEET (3048 MM). |
| EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE |
| BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 |
| PERCENT AWAY FROM THE BUILDING. |
| |
| 9) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR |
| R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY COMPLIANCE |
| FORMS AS REQUIRED. |
| |
| 10) SHOW COMPLIANCE WITH EMERGENCY ESCAPE AND RESCUE |
| OPENING REQUIREMENTS. FBC-R310 |
| |
| 11) SHOW COMPLIANCE WITH EGRESS REQUIREMENTS. FBC-R311 |
| |
| 12) THE VALUE OF $10,000.00 SPECIFIED ON THE |
| APPLICATION IS THE ARCHITECT'S FEES BASED ON THE |
| DOCUMENTS THAT WERE SUBMITTED. FBC 109.3 BUILDING |
| PERMIT VALUATION. FOR PERMITTING PURPOSES, VALUATION OF |
| BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE |
| TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, |
| INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND |
| DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; |
| EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY |
| INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL |
| CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, |
| MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE |
| CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET |
| BY THE BUILDING OFFICIAL. |
| |
| 13) SUBMIT TWO SETS OF MECHANICAL, ELECTRICAL AND |
| PLUMBING PLANS. SUB-PERMITS ARE REQUIRED FOR THE |
| MECHANICAL, ELECTRICAL AND PLUMBING WORK. FBC |
| 107..3.5.3 & 105.1 |
| |
| DUE TO THE AMOUNT OF MISSING INFORMATION, A COMPLETE |
| REVIEW IS NOT POSSIBLE AT THIS TIME. |
| |
| |
| |
| |