Plan Review Notes
Plan Review Notes For Permit 17020045
Permit Number 17020045
Review Stop P
Sequence Number 1
Notes
Date Text
2017-02-17 13:10:141ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. SHT. P101 SANITARY RISER.
 A) THE DISHWASHER CAN NOT CONNECT TO A SEPARATE TRAP IT
 SHALL COMPLY WITH FBC RES P2717.2 OR P2717.3
 B) THE BRANCH DRAINS FOR BOTH WATER CLOSETS SHALL BE A
 MIN OF 3". PER FBC RES P3005.1.4
  
 2. SHUT OFF VALVES FOR THE STACKABLE WASHING MACHINE
 SHALL BE ACCESSIBLE. PER FBCRES P2903.9.3
  
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  


Account Summary | Usage Policy | Privacy Policy