Plan Review Notes For Permit 17020045 |
Permit Number |
17020045 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2017-02-17 13:10:14 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. SHT. P101 SANITARY RISER. | | A) THE DISHWASHER CAN NOT CONNECT TO A SEPARATE TRAP IT | | SHALL COMPLY WITH FBC RES P2717.2 OR P2717.3 | | B) THE BRANCH DRAINS FOR BOTH WATER CLOSETS SHALL BE A | | MIN OF 3". PER FBC RES P3005.1.4 | | | | 2. SHUT OFF VALVES FOR THE STACKABLE WASHING MACHINE | | SHALL BE ACCESSIBLE. PER FBCRES P2903.9.3 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|