Plan Review Notes
Plan Review Notes For Permit 17010802
Permit Number 17010802
Review Stop B
Sequence Number 1
Notes
Date Text
2017-01-30 15:47:30BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17010802
 ADD: 2 HARVARD CIR. SUITE # 500
 CONT: FISHER CONTRACTING
 TEL: 561-691-4716
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN. 30/ 2014
 ACTION: DENIED
  
 1) SHEET 3.1 SHOWS A NEW DOOR WAY BETWEEN SUITE 500 AND
 SUITE 450. THE WALL BETWEEN THE (2) UNITS IS DRAWN
 THICKER THAN THE OTHER WALLS. THE WALL IS DRAWN IN
 WIDTH JUST AS AN 8 INCH CBS BLOCK WALL, IS THIS A 8
 INCH BLOCK WALL REQUIRING A LINTEL AND COLUMNS?
 107.2.1.3 ADDITIONAL INFORMATION REQUIRED.
  
 2) SHEET 3.1 INDICATES THE NEW OFFICE SPACE TO HAVE AN
 OPEN OFFICE CONCEPT. PLEASE PROVIDE A LIFE SAFETY PLAN
 THAT SHOWS THE FURNATURE/ CUBICAL LAYOUT AND EXIT
 ACCESS FOR COMPLIANCE WITH:
 2014 FBC-B TABLE 1014.3.
  
 3) SHEET 3.1 WAITING ROOM # 100 FOR SUITE 450 SHOWS A
 PASS THROUGH WINDOW, IT APPEARS THERE IS A COUNTER, THE
 PLANS DO NOT PROVIDE IF THIS AREA IS FOR A SECOND
 RECEPTIONIST, IF THE COUNTER IS FOR CHECK WRITING, MAY
 NEED TO COMPLY WITH SECTION 904.3.3 CHECK WRITING
 SURFACES OF THE 2014 ACCESSIBILITY CODE. WHERE
 PROVIDED, CHECK WRITING SURFACES SHALL COMPLY WITH
 902.3.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  