2017-01-20 09:25:23 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17010634 |
| W. P. B. MASTER: 16080300 |
| ADD: 5016 S. DIXIE HWY. |
| CONT: THERMA SEAL ROOF SYSTEMS LLC |
| TEL: 561-223-2096 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. JAN. 20/2017 |
| ACTION: DENIED |
| |
| 1) THE DESIGNER OF RECORD HAS NOT REVIEWED THE ROOFING |
| PRODUCT APPROVAL NOR APPLIED THEIR SHOP DRAWING STAMP |
| OF APPROVAL. |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION FBC 107.3.4.1 PRODUCT APPROVALS. THOSE |
| PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| |
| 2) THE CONTRACTOR OF RECORD FAILED TO PRODUCE THE |
| NECESSARY SHEETS OF THE PRODUCT APPROVAL NECESSARY FOR |
| A THOROUGH REVIEW. MISSING SHEETS FROM ROOFING APPROVAL |
| FL16440-R9 APPENDIX SHEETS 2-3. ADDITIONAL INFORMATION |
| REQUIRED. 107.2.1.3, MISSING DOCUMENTS. |
| |
| 3) THE SUB-SYSTEMS FROM APPENDIX 1, PAGES 45 OF 46 |
| SYSTEM NUMBER R-53 IS CIRCLED. EXISTING ROOF SYSTEM |
| WITH GRANULE-SURFACED MODIFIED BITUMEN CAP SHEET |
| INSTALLED OVER TECTUM ROOF DECK. APPENDIX SHEETS 2-3 |
| USE AND LIMITATION OF THE VARIOUS SUB-SYSTEMS NOTE |
| NUMBER 12 THE EXISTING ROOF SYSTEM SHALL BE CAPABLE OF |
| RESISTING PROJECT DESIGN PRESSURES ON ITS OWN MERIT TO |
| THE SATISFACTION OF THE AHJ, AS DOCUMENTATION THROUGH |
| FIELD UPLIFT TESTING IN ACCORDANCE WITH TAS 124. |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED |
| BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL |
| ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING |
| SYSTEM, MATERIALS, FASTENING |
| REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE |
| RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT |
| EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE |
| WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE |
| OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE |
| SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION |
| DOCUMENTS. |
| |
| 4) UNDER THE ISSUED PERMIT SET OF PLANS THE WIND DESIGN |
| CRITERIA IS FOUND ON SHEET S-2. |
| 170 VULT |
| 131.75 VASD |
| EXPOSURE C |
| WINDOW AND DOOR PRESSURES FOR REPLACED UNITS. |
| THE MEAN ROOF HEIGHT NOT PROVIDED, NOR THE ROOF |
| PRESSURES AT 10 SQ. FT. FOR ROOF ZONES 1, 2 OR 3. |
| 2014 FBC-B 1603.1.4 WIND DESIGN DATA. |
| (3.) WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE |
| THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. |
| HEIGHT AND EXPOSURE. |
| (5.) DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR |
| COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY |
| DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL |
| RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ |
| M2). |
| TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| BUILDING. |
| 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. |
| NOTE IF THE DESIGN CRITERIA IS BY ANOTHER DESIGN |
| PROFESSIONAL (ENGINEER OF RECORD) A DELEGATE ENGINEER |
| THEN THE ROOF TOP DESIGN PRESSURES MUST BE REVIEWED BY |
| THE ENGINEER OF RECORD. |
| 61G15-30.003 ENGINEERING DOCUMENT CLASSIFICATION. FL |
| 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL FORWARD |
| THE DELEGATED ENGINEERING DOCUMENTS TO THE ENGINEER OF |
| RECORD FOR REVIEW. |
| |
| 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |