Date |
Text |
2017-08-01 11:14:23 | 08/01/17 YANIL ESPINAL E-MAILED BACK. THEY ARE GETTING |
| THE PRODUCT APPROVALS TO RE-SUBMIT. PLANS IN BACK LARGE |
| PLANS SHELF UNDER "J". JG. |
| |
| |
| |
| BUILDING REVIEW APPROVED WITH PROVISO: |
| 1- FLAT ROOF NOA 14-0529.02 SUBMITTED: PROVIDE SIGNED |
| AND SEALED RAS 117 CALCULATIONS AS REQ'D GENERAL |
| LIMITATION #7. |
| |
| 2- ARCHITECT TO REVISE THE DESIGN PRESSURES FOR THE |
| OVERHEAD GARAGE DOOR TO CORRESPOND TO EXPOSURE "D". SEE |
| SHEET A3.1 |
| |
| 3- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: |
| A) BALCONY DECK UNDERLAYMENT. NOTE: NEED PRODUCT |
| APPROVAL THAT IS DESIGNED TO BE USED WITH THE SPECIFIC |
| DECK FINISH MATERIAL TO BE INSTALLED IN THIS HOUSE. IN |
| ADDITION CLEARLY IDENTIFY SPECIFIC ASSEMBLY TO BE |
| INSTALLED AND PROVIDE SIGNED AND SEALED RAS 117 |
| CALCULATIONS IF REQUIRED. |
| |
| B) ROOF CLAY TILE. NOA 12-0210.01 SUBMITTED EXPIRED ON |
| 02/01/16. |
| |
| C) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL |
| FOR LISTED ADHESIVES. |
| |
| D) OVERHEAD GARAGE DOOR THAT MEETS THE DESIGN PRESSURES |
| CALCULATED BY THE ARCHITECT OF RECORD. COORDINATE WITH |
| ITEM #2 ABOVE. |
| |
| E) SINGLE HUNG WINDOWS. NEED LARGE MISSILE IMPACT |
| RESISTANT PRODUCT APPROVAL. NOA 15-0512.08 SUBMITTED IS |
| FOR SMALL MISSILE IMPACT RESISTANT. |
| |
| F) WINDOW MULLIONS AS SHOWN ON PLANS. AND, SPECIFY |
| MULLION SIZE. |
| |
| G) FIXED WINDOWS AS SPECIFIED ON PLANS. |
| |
| H) GUEST HOUSE EXTERIOR SWING DOOR AS SHOWN ON PLANS. |
| |
| 4- ARCHITECT OF RECORD TO REVIEW AND APPROVE ABOVE |
| PRODUCT APPROVALS. |