Date |
Text |
2017-01-09 09:56:29 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) THE PROJECT IS LOCATED IN EXPOSURE D AND HAS A MEAN |
| ROOF HEIGHT OF ABOUT 23 FEET. THE WINDLOAD CALCULATIONS |
| FROM AL-FAROOQ CORPORATION WERE DONE FOR EXPOSURE C |
| WITH A MEAN ROOF HEIGHT OF 20 FEET. FBC - R301.2.1 & |
| R301.2.1.4.3 |
| |
| 2) PROVIDE STRUCTURAL DRAWINGS AND DETAILS FOR THE NEW |
| LANDING, STEPS AND BALUSTRADE ON THE PLANS. FBC 107.2.1 |
| |
| 3) SHOW COMPLIANCE WITH FBC-R314.3.1 ALTERATIONS, |
| REPAIRS AND ADDITIONS. WHEN ALTERATIONS, REPAIRS OR |
| ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE |
| SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING |
| DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL BE |
| EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW |
| DWELLINGS. |
| |
| 4) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE |
| CONCRETE ROOF TILE AND THE DOUBLE CASEMENT WINDOWS. |
| |
| 5) THE PLANS SPECIFY NOA NO. 15-0416.02 FOR THE |
| CASEMENT WINDOWS ON SHEET A-03. THE PRODUCT APPROVAL |
| THAT WAS SUBMITTED, NOA NO. 15-0416.01, IS FOR SINGLE |
| CASEMENT WINDOWS. PLEASE CORRECT. |
| |
| 6) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A |
| RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| COMMENTS HAS BEEN ADDRESSED. |
| |
| |
| |
| |