2017-01-12 15:15:53 | JOB PERMIT NUMBER: 16120061 | | JOB ADDRESS: 1110 18TH STREET | | WEST PALM BEACH FLORIDA | | DATE: JANUARY 12, 2017 | | ELECTRICAL PLAN REVIEW COMMENTS | | | | - THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, | | (RESIDENTIAL FLORIDA BUILDING CODE) AS WELL AS THE CITY | | OF WEST PALM BEACH AMENDMENTS. SEE BELOW A LIST OF | | ITEMS NOTED. | | | | 1] PROVIDE A MAIN DISCONNECT OUTSIDE NEAREST THE POINT | | OF ENTRANCE OF THE SERVICE CONDUCTORS IN ACCORDANCE | | WITH FBC-R SECTION E3601.6.2. | | | | 2] PROVIDE A SWITCHED LIGHTING OUTLET FOR EXTERIOR | | EGRESS ILLUMINATION ON THE STORAGE SHED PER FBC-R | | SECTION E3903.3. | | | | - PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED ITEMS. IF YOU HAVE FURTHER QUESTIONS, PLEASE | | DON'T HESITATE TO CONTACT ME DIRECTLY. | | | | 1ST REVIEW | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | |
|