Date |
Text |
2016-12-19 16:56:19 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. THE 3" STACK FOR WASHING MACHINE ON SECOND FLOOR | | SHALL CONNECT TO BUILDING DRAIN DOWNSTEAM OF POWDER | | ROOM BATH. PER FBC RES P3108.1 | | | | 2. THE VENT ON THE WC IN THE FIRST FLOOR GUEST BATH | | SHALL BE CONNECTED TO THE LAVATORY STACK NOT WC . PER | | FBC RES P3101.2.1 | | | | 3. A CLEAN OUT IS REQUIRED AT THE BASE OF THE WASTE AND | | SOIL STACKS. FBC RES P3005.2.6 | | | | 4. REMOVE NOTES ON THE RISER THAT REFER TO EXIST. IF | | THIS IS NEW CONSTRUCTION. PER WPB AMEND TO FBC 107.2.1 | | |
|