Plan Review Notes For Permit 16110104 |
Permit Number |
16110104 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2016-11-02 14:27:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THIS PARCEL IS LOCATED IN EXPOSURE C. SEE THE LARGE | | OPEN AREA 400 FEET TO THE NORTH. FBC 5TH EDITION | | RESIDENTIAL 301.2.1.4.1. THE NORTH QUADRANT DOES NOT | | HAVE EXPOSURE B SURFACE ROUGHNESS CONDITIONS, SO THE | | STRUCTURE IS IN EXPOSURE C. | | | | PROVIDE MEAN ROOF HEIGHT. 15' REQUIRES 95.7 PSF, 20' | | REQUIRES -102. | | |
|