Plan Review Notes
Plan Review Notes For Permit 16110010
Permit Number 16110010
Review Stop I
Sequence Number 1
Notes
Date Text
2016-11-16 09:55:181ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL, EXISTING
 BUILDING
  
 WORK ORIGINALLY APPLIED FOR ON 02/28/2005 AND IS
 DOCUMENTED AS COMPLETE ON 03/09/2005, BUT WITH NO
 APPROVED INSPECTION HISTORY.
  
 REVIEW FOR RE-ISSUANCE OF PERMIT NUMBER 05021507 FOR
 FLAT AND SLOPED RE-ROOFING OF WORK THAT WAS COMPLETED
 IN 2005. THERE IS NO APPROVED INSPECTION HISTORY. THE
 OWNER HAS ENGAGE A LICENSED ROOFING CONTRACTOR. THE
 CONTRACTOR AND OWNER MUST ENGAGE A LICENSED ENGINEER OR
 ROOFING CONSULTANT TO PERFORM AN INVESTIGATION AND/OR
 TESTS TO ASSURE ALL THE REQUIREMENT OF THE PERMIT WERE
 SATISFACTORILY COMPLETED. PURSUANT TO FBC 110.3.9.1 AND
 FBC 117, A WRITTEN REPORT WITH PHOTOGRAPHIC EVIDENCE IS
 REQUIRED. SUCH REPORT SHALL INCLUDE BUT NOT BE LIMITED
 TO CERTIFYING THE FOLLOWING INSPECTIONS.
  
 ROOF SHEATHING RE-NAILING
 UNDERLAYMENT AND UNDERLAYMENT FASTENER SPACING
 INCLUDING ALL METAL AND DRIP EDGE INSTALLATION.
 ROOFING MATERIAL INSTALLATION, AND FINAL.
 THE REMAINING USEFUL LIFE OF THE ROOF COVERING SHALL BE
 ESTIMATED AND DOCUMENTED IN THE REPORT. .
  
 FBC 110.3.9.1 AFFIDAVIT FOR INSPECTION. WITH SPECIFIC
 PRIOR APPROVAL OF, AND IN A FORMAT
 ACCEPTABLE TO THE BUILDING OFFICIAL, AN AFFIDAVIT FOR
 CERTIFICATION OF INSPECTION MAY BE
 ACCEPTED FROM THE PERMIT QUALIFIER; WHEN ACCOMPANIED BY
 EXTENSIVE PHOTOGRAPHIC
 EVIDENCE OF SUFFICIENT DETAIL TO DEMONSTRATE CODE
 COMPLIANCE.
  
 FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR
 TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE
 TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN
 APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY.
  
 DEPENDING ON THE ACCEPTABILITY OF THE REPORT AND
 INSPECTION AFFIDAVIT, THE MATTER MAY BE RESOLVED
 WITHOUT FURTHER NEED TO SCHEDULE ANY INSPECTION. PLEASE
 COORDINATE WITH ME DIRECTLY UPON FURTHER SUBMITTAL.
  
 ALTERNATIVELY, A RE-SUBMITTAL MAY BE ACCEPTED UNDER
 THIS PERMIT RECORD FOR A NEW ROOFING SYSTEM. ADDITIONAL
 REVIEW AND FEES WILL APPLY.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  
2016-11-15 09:31:5311/15/16 APPLICATION ON STEVE KENNEDY'S DESK. JG.
2016-11-15 08:49:59TO SAK DESK TO DISCUSS W/RBROWN.
2016-11-03 16:43:00JGOMEZ'S DESK