Date |
Text |
2016-11-22 16:55:08 | 1ST REVIEW |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER LL |
| CITY OF WEST PALM BEACH |
| DEVELOPMENT SERVICES |
| BUILDING DIVISION |
| 561-805-6711 |
| [email protected] |
| |
| PLUMBING COMMENTS: |
| |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| |
| 1. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE |
| THEIR PRINTED NAME AND SIGNATURE ON THE PLAN PER FBC |
| 107. |
| 2. PLANS ARE INELIGIBLE. NO PLUMBING REVIEW PERFORMED |
| AT THIS TIME. |
| |
| FBC-107.1 GENERAL - FAC 61G1-16.004 - A TITLE BLOCK |
| MUST APPEAR ON ALL ARCHITECTURAL OR INTERIOR DESIGN |
| DRAWINGS AND SPECIFICATION IDENTIFICATION SHEETS THAT |
| ARE REQUIRED TO BE SIGNED AND SEALED. THE TITLE BLOCK |
| MUST, AT A MINIMUM, CONTAIN THE FOLLOWING INFORMATION: |
| (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. |
| (2) FIRM LICENSE NUMBER. |
| (3) NAME OR IDENTIFICATION OF PROJECT. |
| (4) DATE PREPARED. |
| (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. |
| (6) THE PRINTED NAME AND THE LICENSE/REGISTRATION |
| NUMBER OF THE PERSON SEALING THE DOCUMENT. |
| (7) THE DATE OF PLANS REVISION, IF THE PLANS ARE |
| REVISED. |
| |
| 61G1-16.001 ARCHITECT?S AND INTERIOR DESIGNER?S SEAL. |
| EACH ARCHITECT AND INTERIOR DESIGNER SHALL ACQUIRE A |
| SEAL WITH WHICH SHE OR HE SHALL IDENTIFY ALL PLANS, |
| SPECIFICATIONS OR REPORTS PREPARED OR ISSUED BY HER OR |
| HIM AND FILED FOR PUBLIC RECORD. THE SEAL SHALL BE |
| CAPABLE OF LEAVING A PERMANENT INK REPRESENTATION OR |
| OTHER FORM OF EMBOSSING OR OPAQUE AND PERMANENT |
| IMPRESSION, WHICH ALSO MAY BE COMPUTER GENERATED |
| IMPRESSIONS, ON THE SURFACE OF PRINTS OR OTHER |
| DUPLICATIONS OF DRAWINGS, AND, AS APPROPRIATE, UPON |
| SPECIFICATION PAGES, AND OTHER ARTICLES OF SERVICE. |
| WHERE REQUIRED, ELECTRONIC FILES MAY BE SEALED IN |
| ACCORDANCE WITH RULE 61G1-16.005, F.A.C. |
| |
| FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE |
| DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH |
| INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES |
| SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE |
| TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE |
| FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| DESIGN. (SEE ALSO SECTION 107.3.5). |
| |