2017-08-29 18:24:50 | 3RD REVIEW |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER LL |
| CITY OF WEST PALM BEACH |
| DEVELOPMENT SERVICES |
| BUILDING DIVISION |
| 561-805-6711 |
| [email protected] |
| |
| PLUMBING COMMENTS: |
| |
| PREVIOUS COMMENT NOT COMPLIED. 3RD REQUEST |
| |
| 8. THE VALUATION OF THE JOB APPEARS TO BE A LITTLE LOW |
| PLEASE PROVIDE A DETAILED, QUANTITY ESTIMATES, AND/OR |
| BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO |
| MEET THE |
| APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING |
| PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL |
| BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, |
| RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, |
| MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING |
| ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE |
| LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION |
| COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), |
| AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. |
| FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| BUILDING OFFICIAL. PER WPB AMEND TO FBC 109.3 |
| |
| PREVIOUS COMMENTS 2ND REQUEST NOT COMPLIED |
| |
| 1. VALVES FOR THE STACKABLE WASHING MACHINES SHALL BE |
| ACCESSIBLE. PER FBC PL 606.3 |
| |
| 2.SHT. S2 #7 UNDER PLUMBING NOTES AIR CHAMBERS ARE NOT |
| APPROVED A WATER-HAMMER ARRESTOR SHALL BE INSTALLED |
| WHERE QUICK-CLOSING VALVES ARE UTILIZED. PER FBC PL |
| 604.9 |
| |
| 3.THE UPSTAIRS BATHROOM WITH A TUB IS NOT SHOWN ON THE |
| RISER PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 |
| |
| DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND |
| THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON |
| RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. |
| |
| WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES |
| AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE |
| AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. |
| |