Date |
Text |
2017-01-09 08:53:05 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| |
| 2ND REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PLAN PG. A-1 INDICATES TWO DIFFERENT EXISTING |
| ELEVATIONS. PLEASE CLARIFY. |
| 2. PLAN PG. A-1 LEVEL OF WORK STATES "THERE IS NO WORK |
| BEING DONE OTHER THAN PAINTING AND MINOR REPAIRS". |
| MODIFY STATEMENT TO REFLECT ALL PROPOSED WORK PER FBC |
| 2014 EXISTING BUILDING. |
| 3. ENERGY SUBMITTAL DOES NOT REFLECT PROPOSED AREA OF |
| WORK. AREA CALCULATIONS PER PLAN PG. A-1 STATES |
| CONVERTED GARAGE AS 270 SQ. FT. ENERGY SUBMITTAL USES |
| 486 SQ. FT. PLEASE CLARIFY. |
| 4. PROVIDE DETAILS FOR OHD IN-FILL AND EXISTING |
| EXTERIOR WALLS AND CEILING. INDICATE REQUIRED |
| INSULATION FOR WALLS AND CEILING. THE BUILDING THERMAL |
| ENVELOPE SHALL MEET THE REQUIREMENTS OF TABLE R402.1.1 |
| BASED ON THE CLIMATE ZONE SPECIFIED IN CHAPTER 3. |
| 5. A/C COMPRESSOR ENCROACHES ON EMERGENCY ESCAPE & |
| RESCUE OPENING PER FBC R310. |
| 6. CERTIFICATION LETTER BY DESIGNER OF RECORD JAMES |
| PHILIP DRAGO, AIA ONLY ADDRESSES THE PLUMBING AND |
| ELECTRICAL WORK COMPLETED FOR THE NEW MASTER SUITE. |
| 7. PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE |
| PREVIOUSLY COMPLETED WORK TO BE MADE ACCESSIBLE AND |
| OPEN FOR INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION |
| FOR ALL CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO |
| FBC 110 & FBC 117. |
| THE BUILDING OFFICIAL MAY REQUIRE TESTS OR TEST REPORTS |
| AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE TO BE MADE |
| AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN APPROVED |
| TESTING LABORATORY OR OTHER APPROVED AGENCY. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| REVIEWED SHEETS DETACHED AND MARK VOID. |
| |
| |
| |