2016-11-03 10:38:32 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER ? PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 2ND REVIEW |
| RESULTS: DENIED |
| |
| CATEGORY IV SUNROOM. ELECTRICAL, MECHANICAL, ENERGY AND |
| IMPACT NOT REQUIRED. |
| |
| 1. INCLUDE SGD AT MASTER BEDROOM ON APPLICATION OR |
| REMOVE IT FROM PLANS. |
| 2. ENCLOSING THE SCREEN ROOM WITH GLASS VOIDS THE |
| EGRESS REQUIREMENTS FOR BEDROOM #2. DEMONSTRATE HOW YOU |
| WILL PROVIDE EGRESS FROM THIS ROOM. |
| 3. PROVIDE DEMENSIONS FOR ROUGH OPENINGS OF MASONRY |
| WALLS. PROVIDE FRAMING DETAIL FOR EACH OPENING. |
| 4. DESIGNER TO PRINT NAME AND SIGN PLANS. |
| 5. SHOW LOCATION OF GFI AND SMOKE DETECTOR LISTED ON |
| PLANS OR REMOVE FROM PLANS. |
| |
| |
| R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. |
| BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM |
| SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND |
| RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE |
| SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS |
| SHALL BE REQUIRED IN EACH SLEEPING ROOM. WHERE |
| EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY |
| SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES |
| (1118 MM) MEASURED FROMTHE FINISHED FLOOR TO THE BOTTOM |
| OF THE CLEAR OPENING. WHERE A DOOR OPENING HAVING A |
| THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES AS |
| AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS PROVIDED |
| WITH A BULKHEAD ENCLOSURE, THE BULKHEAD ENCLOSURE SHALL |
| COMPLY WITH SECTION R310.3. THE NET CLEAR OPENING |
| DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED |
| BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND |
| RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND |
| RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE |
| ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A |
| WINDOW WELL IN ACCORDANCE WITH SECTION R310.2. |
| EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN |
| DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT |
| OPENS TO A PUBLIC WAY. |
| |
| EXCEPTIONS: |
| 1. BASEMENTS USED ONLY TO HOUSE MECHANICAL EQUIPMENT |
| AND NOT EXCEEDING TOTAL FLOOR AREA OF 200 SQUARE FEET |
| (18.58 M2). |
| 2. THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE |
| PERMITTED TO OPEN INTO A SCREEN ENCLOSURE, OPEN TO THE |
| ATMOSPHERE, WHERE A SCREEN DOOR IS PROVIDED LEADING |
| AWAY FROM THE RESIDENCE. |
| |
| R612.8.4 MASONRY ROUGH OPENINGS. |
| MASONRY ROUGH OPENING DIMENSIONS SHALL BE WITHIN THE |
| TOLERANCES SPECIFIED AT SECTION R606.16 AND, IN |
| ADDITION, SHALL PROVIDE FOR A WINDOW PERIMETER SEALANT |
| JOINT A MAXIMUM OF 1/4 INCHES (6.4 MM) IN WIDTH. |
| |
| FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL |
| INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING |
| DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON |
| RESPONSIBLE FOR THE DESIGN. |
| |
| |
| |