2016-10-11 09:29:55 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER ? PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| THRESHOLD BUILDING |
| |
| 1. SPECIAL INSPECTOR AGREEMENT INCOMPLETE. |
| 1A. PER FS 553.79 THE SPECIAL INSPECTOR MUST BE AN |
| ENGINEER LICENSED UNDER CHAPTER 471, AN ARCHITECT |
| LICENSED UNDER CHAPTER 481 OR A STANDARD INSPCTOR |
| LICENSED UNDER CHAPTER 468. PLEAS REMOVE THE EIT, MR |
| ADAM COON FROM THE AGREEMENT. |
| NOTE. MR COON MAY BE USED TO OBSERVE THE APPLICATION OF |
| WATERPROOFING ON THE BUILDING. |
| 1B. OWNER MUST SIGN AND DATE AGREEMENT (SEE PAGE 4 OF |
| 6). |
| 1C. CONTRACTOR MUST SIGN AND DATE AGREEMENT (SEE PAGE 5 |
| OF 6). |
| |
| 2. SPECIAL INSPECTOR AGREEMENT MUST BE SUBMITTED IN |
| TRIPLICATE. |
| |
| 3. THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY |
| FOR THIS TYPE OF CONSTRUCTION. |
| |
| 4. THE RESIDENT INSPECTOR AGREEMENT SUBMITTED AS PART |
| OF THIS APPLICATION IS NOT REQUIRED. |
| |
| 5. THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. |
| CONSTRUCTION SERVICES DEPARTMENT REQUESTS FOR THRESHOLD |
| BUILDINGS, A SPECIAL INSPECTOR IS REQUIRED BY F.S. |
| 553.79 (5) TO THE MINIMUM INSPECTIONS REQUIRED BY THIS |
| CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED TO BE |
| FILLED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED AND |
| RETURNED TO THIS OFFICE AND REVIEWED AND APPROVED |
| BEFORE PERMIT ISSUANCE WILL TAKE PLACE. CONTACT KEN |
| CONRAD, MANAGER OF SPECIAL INSPECTOR PROGRAM AT (561) |
| 805-6666 FOR FURTHER INFORMATION BEFORE THE PERMIT MAY |
| BE ISSUED. |
| |
| 6. JOB INSPECTOR ? FBC 110.3.7.6 THE BUILDING |
| DEPARTMENT MAY ALLOW A SPECIAL INSPECTOR TO CONDUCT THE |
| MINIMUM STRUCTURAL INSPECTION OF THRESHOLD BUILDINGS |
| REQUIRED BY THIS CODE, SECTION 553.73,FLORIDA STATUTES, |
| WITHOUT DUPLICATIVE INSPECTION BY THE BUILDING |
| DEPARTMENT. THE BUILDING OFFICIAL IS RESPONSIBLE FOR |
| ENSURING THAT ANY PERSON CONDUCTING INSPECTIONS IS |
| QUALIFIED AS A BUILDING INSPECTOR UNDER PART XII OF |
| CHAPTER 468, FLORIDA STATUTES, OR CERTIFIED AS A |
| SPECIAL INSPECTOR UNDER CHAPTER 471 OR 481, FLORIDA |
| STATUTES. INSPECTIONS OF THRESHOLD BUILDINGS REQUIRED |
| BY SECTION 553.79(5), FLORIDA STATUTES, ARE IN ADDITION |
| TO THE MINIMUM INSPECTIONS REQUIRED BY THIS CODE. |
| FBC 110.3.7.4.1 THE SPECIAL INSPECTOR, UPON COMPLETION |
| OF THE BUILDING AND PRIOR TO THE ISSUANCE OF A |
| CERTIFICATE OF OCCUPANCY OR COMPLETION, FILE A SIGNED |
| AND SEALED STATEMENT WITH THE ENFORCEMENT AGENCY IN |
| SUBSTANTIALLY THE FOLLOWING FORM: ?TO THE BEST OF MY |
| KNOWLEDGE AND BELIEF, THE CONSTRUCTION OF ALL |
| STRUCTURAL LOAD-BEARING COMPONENTS DESCRIBED IN THE |
| THRESHOLD INSPECTION PLAN COMPLIES WITH THE PERMITTED |
| DOCUMENTS AND THE SPECIALTY SHORING DESIGN PROFESSIONAL |
| ENGINEER HAS ASCERTAINED THAT THE SHORING AND RESHORING |
| CONFORMS WITH THE SHORING AND RESHORING PLANS SUBMITTED |
| TO THE ENFORCEMENT AGENCY?. |
| |
| 7. NOTICE ONLY. PLEASE CALL THE CITY OF WEST PALM |
| BEACH?S AUTOMATED TELEPHONE INSPECTION LINE @ (561) |
| 805-6700 FOR ALL BUILDING INSPECTIONS FOR AUDITING OF |
| JOBSITE INSPECTIONS. WITHOUT THIS, THE PERMIT EXPIRES |
| IN 6 MONTHS WHICH WILL RESULT IN ?ABANDONMENT OF JOB, |
| NO INSPECTION ACTIVITY?. THE PERMIT WILL BECOME |
| EXPIRED. |
| |
| 8. PLEASE PROVIDE A SITE PLAN SHOWING THE PROPERTY |
| LINES, CONSTRUCTION AREAS, STAGING AREAS, HOW THE |
| OCCUPANTS OF THE BUILDING WILL BE SAFE GUARDED DURING |
| THEIR ENTRY AND EXIT OF THE BUILDING. SHOW COMPLIANCE |
| WITH 2014 FBC 3306.7 ? COVERED WALKWAYS, INCLUDING |
| LIGHTING FOR THE EXIT DISCHARGE. 2014 FBC 3310.2 ? |
| MAINTENANCE OF MEANS OF EGRESS. REQUIRED MEANS OF |
| EGRESS SHALL BE MAINTAINED AT ALL TIMES DURING |
| CONSTRUCTION, DEMOLITION, REMODELING OR ALTERATIONS AND |
| ADDITIONS TO ANY BUILDING. |
| |
| 9. IF SCAFFOLDING EXTENDS BEYOND THE PRIVATE PROPERTY |
| AND ONTO CITY RIGHT OF WAY, ENGINEERING WILL REQUIRE |
| RIGHT OF WAY PERMITS. PLEASE CONTACT MANNY GONZALEZ AT |
| THE ENGINEERING DEPARTMENT ? (561) 494-1085. |
| 9A. IF SCAFFOLDING IS TO BE USED FOR THE HEIGHT OF THE |
| BUILDING, PLEASE PROVIDE HOW THE SCAFFOLDING WILL BE |
| BUILT AS WELL AS HOW THE SCAFFOLDING WILL BE ANCHORED |
| TO RESIST LATERAL WIND LOADING. THERE APPEARS SAND |
| BLASTING WILL ALSO BE AN ELEMENT OF THE OPERATION, HOW |
| WILL THE SANDBLASTING BE CONTAINED, WILL THERE BE WIND |
| SCREENS, IF SO PLEASE PROVIDE WHAT ELEMENTS WILL BE |
| INTRODUCED TO KEEP THE SCAFFOLDING FROM MOVING WITH THE |
| LATERAL EFFECT OF WIND ON THE WIND SCREENS. AT WHAT |
| SAFETY FACTOR ARE THESE ELEMENTS FACTORED? 107.2.1.3 |
| ADDITIONAL INFORMATION. 2014 FBC 3302.1 & 3306.1. |
| |
| 10. PROVIDE COMPLIANCE WITH FBC 3309.1 WHERE REQUIRED. |
| ALL STRUCTURES UNDER CONSTRUCTION, ALTERATION OR |
| DEMOLITION SHALL BE PROVIDED WITH NO FEWER THAN ONE |
| APPROVED PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH |
| SECTION 906 AND SIZED FOR NOT LESS THAN ORDINARY HAZARD |
| AS FOLLOWS: |
| 10A. AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE |
| COMBUSTIBLE MATERIALS HAVE ACCUMULATED. |
| 10B. IN EVERY STORAGE AND CONSTRUCTION SHED. |
| 10C. ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE |
| PROVIDED WHERE SPECIAL HAZARDS EXIST, SUCH AS THE |
| STORAGE AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS. |
| |
| 11. DURING RESTORATION WORK ON BALCONIES, DEMONSTRATE |
| HOW THE TENANTS WILL BE SAFE GUARDED FROM THE WORK AREA |
| AND EGRESS ONTO THE BALCONIES. FBC 3306.1 PROTECTION |
| REQUIRED. |
| |
2016-10-04 11:07:10 | ASSURE NO RIGHT-OF-WAY PERMIT REQUIRED AND PROTECTION |
| OF THE PUBLIC IS PROVIDED. SEE ALSO THE RE-ROOF PERMIT |
| AS THESE ISSUES WERE DEALT WITH THERE AND MAY ALREADY |
| BE RESOLVED. REMOVED ZONING STOP & ROUTED TO CTHROOP. |