Plan Review Notes
Plan Review Notes For Permit 16090860
Permit Number 16090860
Review Stop NFIP
Sequence Number 2
Notes
Date Text
2017-03-23 14:07:00NATIONAL FLOOD INSURANCE PROGRAM (NFIP)
 W. P. B. PERMIT: 16090860
 ADD: 1301 SUMMIT BLVD/ LORIKEET BIRD EXHIBIT
 CONT: GAST
 TEL: 561-281-1001
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2ND REVIEW
 DATE: THURS. MARCH 23/2017
 ACTION: DENIED
  
 1) THIS PROPERTY IS ALSO LOCATED IN A FLOOD ZONE. FBC
 BUILDING 1612 AND CITY OF WPB CODE OF ORDINANCES
 SECTION 94-546. STRUCTURE IS LOCATED IN AN "A 7" FLOOD
 ZONE, BFE ELEVATION 12 FEET NGVD. A FLOOD ELEVATION
 CERTIFICATE WILL BE REQUIRED. THE CITY OF WEST PALM
 BEACH IS STILL USING THE 1929 NGVD ELEVATION DATUM. NO
 FIS FOR THIS LOCATION.
 IMPORTANT CHANGE!!!!
 PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS
 REQUIRE AN ADDITIONAL (1FOOT) FREEBOARD OF ELEVATION.
 CITY ORDINANCE CHANGE SEPT. 12/2016. PLEASE ALSO NOTE
 FOR FUTURE WORK IN THE CITY?S FLOOD ZONE AREAS, THE
 CITY COMMISSION & MAYOR WILL BE CHANGING THE FREEBOARD
 REQUIREMENTS TO (2 FOOT) FREEBOARD IN THE UPCOMING
 MONTHS. ALSO ON ALL FLOOD ZONE CERTIFICATES THE
 LATITUDE AND LONGITUDE ARE TO BE FILLED OUT WITH THE
 FRONT CENTER OF THE STRUCTURE BEING THE POINT GIVEN.
 DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE
 REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES
 REQUIRED:
 (2.1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF
 THE PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH
 FLOOR HEIGHT. 107.2.5.1 DESIGN FLOOD ELEVATIONS.
 107.3.5.1.1(1) MINIMUM PLAN REVIEW COMMERCIAL
 BUILDINGS. FLOOD HAZARD AREAS, FLOOD ZONES, AND DESIGN
 FLOOD ELEVATIONS.
  
 (2.2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND
 ELEVATION CERTIFICATE IS REQUIRED. REQUIRED
 INSPECTIONS. 110.3.( 1.2.) IN FLOOD HAZARD AREAS, UPON
 PLACEMENT OF THE LOWEST FLOOR, INCLUDING BASEMENT,
 AND PRIOR TO FURTHER VERTICAL CONSTRUCTION, THE
 ELEVATION CERTIFICATION, REQUIRED IN SECTION 1612.5,
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL.
  
 (2.3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY
 OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE
 CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR
 ATTENDANTS. REQUIRED INSPECTIONS. 110.3.( 6.) FINAL
 INSPECTION. TO BE MADE AFTER THE BUILDING IS COMPLETED
 AND READY FOR OCCUPANCY.6.1. LOWEST FLOOR ELEVATION. IN
 FLOOD HAZARD AREAS, AS PART OF THE FINAL INSPECTION, A
 FINAL CERTIFICATION OF THE LOWEST FLOOR ELEVATION SHALL
 BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION.
 A/C PADS OR OTHER SLABS FOR GENERATORS
 FEMA NEW FORM AVAILABLE JUNE 13/2016.
 OMB NO. 1660-0008
 EXPIRATION DATE: NOV. 30/2018
 HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM
  