Date |
Text |
2016-10-12 11:34:58 | 1ST REVIEW |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER LL |
| CITY OF WEST PALM BEACH |
| DEVELOPMENT SERVICES |
| BUILDING DIVISION |
| 561-805-6711 |
| [email protected] |
| |
| PLUMBING COMMENTS: |
| |
| 1. SHT. A1.01 SHOWS A SINGLE BATHROOM IN BUILDING C IS |
| THIS FUTURE AND TYPICAL PLEASE CLARIFY. PER WPB AMEND |
| TO FBC 107.2.1 |
| |
| 2. GRAB BARS ARE TO BE MEASURED FROM GRIPPING SURFACE |
| TO FINISH FLOOR. PER FBC ACC 609.4 POSITION OF GRAB |
| BARS. |
| GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR |
| CHILDREN?S USE COMPLYING WITH 604.9, GRAB BARS SHALL BE |
| INSTALLED IN A HORIZONTAL POSITION 18 INCHES (455 MM) |
| MINIMUM AND 27 INCHES (685 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. THE |
| HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A |
| BATHTUB SHALL COMPLY WITH 607.4.1.1 OR 607.4.2.1. |
| |
| 3.TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| THE CENTERLINE OF THE DISPENSER. PER FBC ACC 604.7 |
| |
| 4. PLEASE INDICATE URINAL AS ACCESSIBLE AND SHOW CLEAR |
| FLOOR SPACE. PER FBC ACC 605.2 |
| |
| 5. PLEASE SPECIFY SHEET NUMBER IN THE NOTES ON THE |
| PLUMBING PAGES THAT ARE REFERENCING A SHEETS FOR STORM |
| DRAIN DETAILS. PER WPB AMEND TO FBC 107.2.1 |
| |
| 6. ALL LAVATORY'S IN PUBLIC BATHROOMS SHALL COMPLY |
| WITH.FBC PL 416.5 TEMPERED WATER FOR PUBLIC |
| HAND-WASHING FACILITIES. |
| TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND |
| GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES |
| PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED |
| WATER SHALL BE DELIVERED THROUGH AN APPROVED |
| WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE |
| 1070 OR CSA B125.3. |