Date |
Text |
2016-09-10 09:18:50 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 16090054 |
| ADD: 415 CLEMATIS ST. SUITE # 230 |
| CONT: CUTTING EDGE BUILDING |
| TEL: 561-625-4545 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: SAT. SEPT. 10/ 2016 |
| ACTION: DENIED |
| |
| 1) SHEET A.01 THE FLOOR PLANS INDICATE (2) PASS THRU |
| WINDOWS AND COUNTERS, THE DETAILS FOR BOTH WINDOWS |
| INDICATE A SECTION A04/01-2. THERE IS NO SHEET 4 NOR IS |
| THERE ON THE SHEET INDEX ON THE COVERSHEET. 107.2.1.3 |
| ADDITIONAL INFORMATION IS REQUIRED. |
| FBC-B SAFETY GLAZING 2406.1. |
| FBC-ACCESS. CODE 902.3 HEIGHT. THE TOPS OF DINING |
| SURFACES AND WORK SURFACES SHALL BE 28 INCHES (710 MM) |
| MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR OR GROUND. |
| |
| 2)SHEET A.01. IN THE X-RAY ROOM THERE IS ALSO A WINDOW |
| DETAIL WINDOW A-04/03/4. THERE IS NO SHEET 4 NOR IS |
| THERE ON THE SHEET INDEX ON THE COVERSHEET. 107.2.1.3 |
| ADDITIONAL INFORMATION IS REQUIRED. |
| FBC-B 465 CONTROL OF RADIATION HAZARDS. |
| |
| 3) SHEET A.01 THERE IS NO INFORMATION AS TO SAFE GUARDS |
| FOR RADIATION CONTROL FOR THE FLOOR, WALLS NOR THE |
| FLOOR/ CEILING ABOVE. |
| 465.5.1 SHIELDING. |
| 465.6 DOORS, INTERLOCKS, AND WARNING SYSTEMS. |
| 465.7 RADIATION MONITORING DEVICES. |
| |
| 4) IN REVIEWING SHEET A.01 THERE IS A NOTE ON THE PLANS |
| INDICATING SEE THE DOOR SCHEDULE SHEET A-2 . NO SUCH |
| SHEET ,NO DOOR SCHEDULE, NOT ABLE TO CHECK THE WIDTH OF |
| DOORS, FBC-B 1008.1.1. DOOR # 1 IS EXISTING / |
| RELOCATED, DOOR # 19 IS NEW PLEASE PROVIDE THE FIRE |
| RATING FOR EACH DOOR AND HARDWARE AS WELL AS A COMPLETE |
| SCHEDULE FOR THE REMAINDER OF THE DOORS. |
| |
| 5) SHEET A-03 THE RESTROOM ELEVATIONS SHOW THE WATER |
| CLOSE GRAB BARS CENTER LINED AT 36 INCHES. PLEASE |
| REVIEW THE 2014 FBC-ACCESS. CODE 609.4. THE HEIGHT OF |
| THE GRAB BARS IS MEASURED FROM THE TOP OF THE GRASPING |
| SURFACE NOT CENTERLINE. |
| |
| 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION |
| DEVELOPMENT SERVICES DEPARTMENT |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |