2016-09-10 09:18:50BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16090054
 ADD: 415 CLEMATIS ST. SUITE # 230
 CONT: CUTTING EDGE BUILDING
 TEL: 561-625-4545
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. SEPT. 10/ 2016
 ACTION: DENIED
  
 1) SHEET A.01 THE FLOOR PLANS INDICATE (2) PASS THRU
 WINDOWS AND COUNTERS, THE DETAILS FOR BOTH WINDOWS
 INDICATE A SECTION A04/01-2. THERE IS NO SHEET 4 NOR IS
 THERE ON THE SHEET INDEX ON THE COVERSHEET. 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
 FBC-B SAFETY GLAZING 2406.1.
 FBC-ACCESS. CODE 902.3 HEIGHT. THE TOPS OF DINING
 SURFACES AND WORK SURFACES SHALL BE 28 INCHES (710 MM)
 MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 2)SHEET A.01. IN THE X-RAY ROOM THERE IS ALSO A WINDOW
 DETAIL WINDOW A-04/03/4. THERE IS NO SHEET 4 NOR IS
 THERE ON THE SHEET INDEX ON THE COVERSHEET. 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
 FBC-B 465 CONTROL OF RADIATION HAZARDS.
  
 3) SHEET A.01 THERE IS NO INFORMATION AS TO SAFE GUARDS
 FOR RADIATION CONTROL FOR THE FLOOR, WALLS NOR THE
 FLOOR/ CEILING ABOVE.
 465.5.1 SHIELDING.
 465.6 DOORS, INTERLOCKS, AND WARNING SYSTEMS.
 465.7 RADIATION MONITORING DEVICES.
  
 4) IN REVIEWING SHEET A.01 THERE IS A NOTE ON THE PLANS
 INDICATING SEE THE DOOR SCHEDULE SHEET A-2 . NO SUCH
 SHEET ,NO DOOR SCHEDULE, NOT ABLE TO CHECK THE WIDTH OF
 DOORS, FBC-B 1008.1.1. DOOR # 1 IS EXISTING /
 RELOCATED, DOOR # 19 IS NEW PLEASE PROVIDE THE FIRE
 RATING FOR EACH DOOR AND HARDWARE AS WELL AS A COMPLETE
 SCHEDULE FOR THE REMAINDER OF THE DOORS.
  
 5) SHEET A-03 THE RESTROOM ELEVATIONS SHOW THE WATER
 CLOSE GRAB BARS CENTER LINED AT 36 INCHES. PLEASE
 REVIEW THE 2014 FBC-ACCESS. CODE 609.4. THE HEIGHT OF
 THE GRAB BARS IS MEASURED FROM THE TOP OF THE GRASPING
 SURFACE NOT CENTERLINE.
  
 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  