Plan Review Notes
Plan Review Notes For Permit 16081262
Permit Number 16081262
Review Stop R
Sequence Number 1
Notes
Date Text
2016-09-23 18:28:441- FLAT ROOF MODIFIED BITUMEN NOA 14-0529.02 SUBMITTED:
 CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO BE
 INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE: IF
 SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR
 ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117
 CALCULATIONS WILL BE REQUIRED. ONLY ASSEMBLIES WITH
 GENERAL LIMITATION #7 WILL ALLOW RAS 117 CALCULATIONS.
 ASSEMBLIES WITH GENERAL LIMITATION #9 DON'T ALLOW RAS
 117 CALCULATIONS. SEE LAST PAGE OF NOA SUBMITTED.
  