Plan Review Notes
Plan Review Notes For Permit 16081047
Permit Number 16081047
Review Stop B
Sequence Number 1
Notes
Date Text
2016-09-15 11:58:27RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- CLEARLY SPECIFY SIZE AND TYPE OF EXISTING BEDROOM
 WINDOWS AND TYPE AND SIZE OF PROPOSED BEDROOM WINDOWS
 TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS OF
 SEC. 704 OF FBC-EXISTING BUILDING, 5TH EDITION (2014).
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) ENTRY DOOR, UTILITY DOOR AND REAR DOUBLE DOORS. NEED
 PRODUCT APPROVAL THAT MEETS THE DESIGN PRESSURES AS
 REQUIRED BY SEC. R301.2.1.4 FBC-RESIDENTIAL, 5TH
 EDITION (2014). DOORS SUBMITTED WITH FLORIDA PRODUCT
 APPROVAL FL14569-R5 DON'T MEET THE DESIGN PRESSURES.
 NOTE: THIS BUILDING IS LOCATED IN EXPOSURE "D". NEED
 DOORS THAT MEET THE DESIGN PRESSURES FOR THIS EXPOSURE
 CATEGORY.
  
 3- CLEARLY SPECIFY ON WINDOW MULLION PRODUCT APPROVAL
 SUBMITTED THE SIZE OF WINDOW MULLION TO BE INSTALLED TO
 VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301.2.1.4 FBC-RESIDENTIAL.
  
 4- VALUATION DECLARED IN THE PERMIT APPLICATIONS SEEMS
 TO BE LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS
 SUBMITTED. VALUATION TO INCLUDE ALL LABOR, MATERIALS
 AND CONTRACTORS' OVERHEAD AND PROFIT AS REQUIRED BY
 SEC. 109.3 CITY AMENDMENTS. UPDATE VALUATION AND
 PROVIDE COPY OF SIGNED CONTRACT FOR BUILDING OFFICIAL
 APPROVAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved