Date |
Text |
2016-11-08 10:45:03 | 2ND REVIEW |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER LL |
| CITY OF WEST PALM BEACH |
| DEVELOPMENT SERVICES |
| BUILDING DIVISION |
| 561-805-6711 |
| [email protected] |
| |
| PLUMBING COMMENTS: 2ND REQUEST |
| HAVE NOT COMPLIED |
| |
| 1.SHOW ACCESSIBILITY COMPLIANCE FOR SHOWERS TO COMPLY |
| WITH FBC ACC |
| 608.3 GRAB BARS. |
| GRAB BARS SHALL COMPLY WITH 609 AND SHALL BE PROVIDED |
| IN ACCORDANCE WITH 608.3. WHERE MULTIPLE GRAB BARS ARE |
| USED, REQUIRED HORIZONTAL GRAB BARS SHALL BE INSTALLED |
| AT THE SAME HEIGHT ABOVE THE FINISH FLOOR. |
| 608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS. |
| IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE |
| PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A |
| POINT 18 INCHES (455 MM) FROM THE CONTROL WALL. |
| 608.3.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS. |
| WHERE A SEAT IS PROVIDED IN STANDARD ROLL-IN TYPE |
| SHOWER COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THE |
| BACK WALL AND THE SIDE WALL OPPOSITE THE SEAT. GRAB |
| BARS SHALL NOT BE PROVIDED ABOVE THE SEAT. WHERE A SEAT |
| IS NOT PROVIDED IN STANDARD ROLL-IN TYPE SHOWER |
| COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THREE |
| WALLS. GRAB BARS SHALL BE INSTALLED 6 INCHES (150 MM) |
| MAXIMUM FROM ADJACENT WALLS. |
| 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. |
| IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, |
| FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON |
| THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) |
| MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE |
| SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL |
| 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE |
| SEAT TOWARD THE SHOWER OPENING. |
| 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. |
| IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, |
| FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON |
| THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) |
| MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE |
| SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL |
| 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE |
| SEAT TOWARD THE SHOWER OPENING. |
| 608.4 SEATS. |
| A FOLDING OR NON-FOLDING SEAT SHALL BE PROVIDED IN |
| TRANSFER TYPE SHOWER COMPARTMENTS. A FOLDING SEAT SHALL |
| BE PROVIDED IN ROLL-IN TYPE SHOWERS REQUIRED IN |
| TRANSIENT LODGING GUEST ROOMS WITH MOBILITY FEATURES |
| COMPLYING WITH 806.2. SEATS SHALL COMPLY WITH 610. |
| 610.3 SHOWER COMPARTMENT SEATS. |
| WHERE A SEAT IS PROVIDED IN A STANDARD ROLL-IN SHOWER |
| COMPARTMENT, IT SHALL BE A FOLDING TYPE, SHALL BE |
| INSTALLED ON THE SIDE WALL ADJACENT TO THE CONTROLS, |
| AND SHALL EXTEND FROM THE BACK WALL TO A POINT WITHIN 3 |
| INCHES (75 MM) OF THE COMPARTMENT ENTRY. WHERE A SEAT |
| IS PROVIDED IN AN ALTERNATE ROLL-IN TYPE SHOWER |
| COMPARTMENT, IT SHALL BE A FOLDING TYPE, SHALL BE |
| INSTALLED ON THE FRONT WALL OPPOSITE THE BACK WALL, AND |
| SHALL EXTEND FROM THE ADJACENT SIDE WALL TO A POINT |
| WITHIN 3 INCHES (75 MM) OF THE COMPARTMENT ENTRY. IN |
| TRANSFER-TYPE SHOWERS, THE SEAT SHALL EXTEND FROM THE |
| BACK WALL TO A POINT WITHIN 3 INCHES (75 MM) OF THE |
| COMPARTMENT ENTRY. THE TOP OF THE SEAT SHALL BE 17 |
| INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM |
| ABOVE THE BATHROOM FINISH FLOOR. SEATS SHALL COMPLY |
| WITH 610.3.1 OR 610.3.2. |
| 610.3.1 RECTANGULAR SEATS. |
| THE REAR EDGE OF A RECTANGULAR SEAT SHALL BE 2 1/2 |
| INCHES (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES |
| (380 MM) MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM |
| THE SEAT WALL. THE SIDE EDGE OF THE SEAT SHALL BE 11/2 |
| INCHES (38 MM) MAXIMUM FROM THE ADJACENT WALL. |
| 610.3.2 L-SHAPED SEATS. |
| THE REAR EDGE OF AN L-SHAPED SEAT SHALL BE 2 1/2 INCHES |
| (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES (380 MM) |
| MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM THE SEAT |
| WALL. THE REAR EDGE OF THE ?L? PORTION OF THE SEAT |
| SHALL BE 11/2 INCHES (38 MM) MAXIMUM FROM THE WALL AND |
| THE FRONT EDGE SHALL BE 14 INCHES (355 MM) MINIMUM AND |
| 15 INCHES (380 MM) MAXIMUM FROM THE WALL. THE END OF |
| THE ?L? SHALL BE 22 INCHES (560 MM) MINIMUM AND 23 |
| INCHES MAXIMUM (585 MM) FROM THE MAIN SEAT WALL. |
| |
| 2. SHOW CLEAR FLOOR SPACE FOR SHOWERS . PER FBC ACC . |
| 608.2.1 TRANSFER TYPE SHOWER COMPARTMENTS. |
| TRANSFER TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES |
| (915 MM) BY 36 INCHES (915 MM) CLEAR INSIDE DIMENSIONS |
| MEASURED AT THE CENTER POINTS OF OPPOSING SIDES AND |
| SHALL HAVE A 36 INCH (915 MM) WIDE MINIMUM ENTRY ON THE |
| FACE OF THE SHOWER COMPARTMENT. CLEARANCE OF 36 INCHES |
| (915 MM) WIDE MINIMUM BY 48 INCHES (1220 MM) LONG |
| MINIMUM MEASURED FROM THE CONTROL WALL SHALL BE |
| PROVIDED. |
| 608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS. |
| STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS SHALL BE 30 |
| INCHES (760 MM) WIDE MINIMUM BY 60 INCHES (1525 MM) |
| DEEP MINIMUM CLEAR INSIDE DIMENSIONS MEASURED AT CENTER |
| POINTS OF OPPOSING SIDES AND SHALL HAVE A 60 INCHES |
| (1525 MM) WIDE MINIMUM ENTRY ON THE FACE OF THE SHOWER |
| COMPARTMENT. |
| |
| 3. SHOWER IN STAFF TOILET RM 118 SHALL BE 36" X 36" PER |
| FBC ACC 608.2.1 |
| |
| 4. SHOW ACCESSIBILITY COMPLIANCE FOR WATER FOUNTAIN FBC |
| ACC |
| 602.2 CLEAR FLOOR SPACE. |
| UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE |
| COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH |
| AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE |
| COMPLYING WITH 306 SHALL BE PROVIDED. |
| 602.4 SPOUT HEIGHT. |
| SPOUT OUTLETS SHALL BE 36 INCHES (915 MM) MAXIMUM ABOVE |
| THE FINISH FLOOR OR GROUND. |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |