2016-09-16 18:49:11 | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION BUILDING |
| REVIEW COMMENTS. |
| CODE: FBC 5TH EDITION (2014). |
| |
| 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED |
| BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION |
| (2014). |
| NOTE: NEED ENERGY CALCULATIONS FOR EACH SEPARATE |
| STRUCTURE. |
| |
| 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) |
| FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED |
| PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY |
| IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT |
| CODE. |
| |
| 3- SCOPE OF WORK ON SHEET A-1 CALLS FOR "REPAIR OF 3 |
| EXISTING FIRE DAMAGED TRUSSES PER ROOF PLAN. PROVIDE |
| COMPLETE DETAILS AND SPECIFICATIONS FOR THE TRUSSES |
| REPAIRS. SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION |
| (2014). |
| |
| 4- WINDOW SCHEDULE ON SHEET A-2: WINDOWS #3 AND #4 |
| DON'T COMPLY WITH EGRESS REQUIREMENTS. REVISE STATEMENT |
| SPECIFYING "SINGLE HUNG EGRESS SIZED". SEC. R310 |
| FBC-RESIDENTIAL. |
| |
| 5- VALUATION DECLARED IN THE PERMIT IS TOO LOW BASED ON |
| THE SCOPE OF WORK SHOWN ON PLANS. VALUATION TO INCLUDE |
| ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT |
| AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. |
| 109.3 CITY AMENDMENTS. REVISE VALUATION AS REQUIRED. |
| |
| 6- PROVIDE PRODUCT APPROVAL ( 2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.002(33) FOR: |
| A) PLASTIC SOFFIT VENT AS SPECIFIED ON THE TYPICAL WALL |
| SECTION ON SHEET D1. |
| |
| B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON |
| DETAILS SUBMITTED. |
| |
| 7- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS |
| (INCLUDING THE ONES ALREADY SUBMITTED) AS REQUIRED BY |
| SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| FOR REFERENCE. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| (561)805-6712 |