Date |
Text |
2016-08-23 08:57:03 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER ? PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| DEVELOPMENT SERVICES DEPARTMENT |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| DATE: 8/23/16 |
| |
| 1. CONFLICT BETWEEN VALUE OF CONTRACT $24,241 AND |
| STATED VALUE ON APPLICATION $19,241. PLEASE RECONCILE. |
| 2. PROVIDE POOL BARRIER PER FBC R 4502.17.1 |
| |
| [A] 109.3 BUILDING PERMIT VALUATIONS. |
| THE APPLICANT FOR A PERMIT SHALL PROVIDE AN ESTIMATED |
| PERMIT VALUE AT TIME OF APPLICATION. PERMIT VALUATIONS |
| SHALL INCLUDE TOTAL VALUE OF WORK, INCLUDING MATERIALS |
| AND LABOR, FOR WHICH THE PERMIT IS BEING ISSUED, SUCH |
| AS ELECTRICAL, GAS, MECHANICAL, PLUMBING EQUIPMENT AND |
| PERMANENT SYSTEMS. IF, IN THE OPINION OF THE BUILDING |
| OFFICIAL, THE VALUATION IS UNDERESTIMATED ON THE |
| APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE |
| APPLICANT CAN SHOW DETAILED ESTIMATES TO MEET THE |
| APPROVAL OF THE BUILDING OFFICIAL. FINAL BUILDING |
| PERMIT VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| |
| R4502.17.1 OUTDOOR SWIMMING POOLS. |
| OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER |
| COMPLYING WITH SECTIONS R4501.17.1.1 THROUGH |
| R4501.17.1.14. |
| |
| R4501.17.1.1 |
| THE TOP OF THE BARRIER SHALL BE AT LEAST 48 INCHES |
| (1219 MM) ABOVE GRADE, MEASURED ON THE SIDE OF THE |
| BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. THE |
| MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM |
| OF THE BARRIER SHALL BE 2 INCHES (51 MM) MEASURED ON |
| THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE |
| SWIMMING POOL. WHERE THE TOP OF THE POOL STRUCTURE IS |
| ABOVE GRADE, THE BARRIER MAY BE AT GROUND LEVEL OR |
| MOUNTED ON TOP OF THE POOL STRUCTURE. WHERE THE BARRIER |
| IS MOUNTED ON TOP OF THE POOL STRUCTURE, THE MAXIMUM |
| VERTICAL CLEARANCE BETWEEN THE TOP OF THE POOL |
| STRUCTURE AND THE BOTTOM OF THE BARRIER SHALL BE 4 |
| INCHES (102 MM). |
| |
| |