Plan Review Notes For Permit 16080663 |
Permit Number |
16080663 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2016-08-19 08:43:56 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SPECIFY THE SLOPE OF THE FLAT ROOF (MINIMUM 1/4" PER | | FOOT) AND THE MEAN ROOF HEIGHT OF THE STRUCTURE. FBC | | 107.2.1 AND FBC R 905.15.1 | | | | 2) THE SCOPE OF WORK SPECIFIED ON THE OWNER SIGNED | | CONTRACT THAT WAS SUBMITTED IS FOR A REROOF WITH | | HYDRO-STOP FL17253.3 AND DOES MATCH THE PRODUCT | | APPROVAL THAT WAS SUBMITTED (FL17649 GAF UNITED | | COATINGS UNISIL HS ROOF COATING). FBC 107.2.1 | | | | 3) THE PRODUCT APPROVAL FOR THE ROOF COATING HAS BEEN | | REVISED. SUBMIT TWO SETS OF THE REVISED PRODUCT | | APPROVALS WHICH ARE FL17649-R2. |
|