Plan Review Notes For Permit 16080366 |
Permit Number |
16080366 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2016-08-10 06:40:51 | BUILDING PROVISO: | | ASPHALT SHINGLES 1507.2.8UNDERLAYMENT APPLICATION. | | ROOFS WITH LESS THAN 4/12 PITCH SHALL BE TWO LAYERS | | APPLIED | | IN THE FOLLOWING MANNER. APPLY A 19-INCH (483 MM) STRIP | | OF UNDERLAYMENT FELT PARALLEL TO AND STARTING AT THE | | EAVES, | | FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE | | EAVE, | | APPLY 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT, | | OVERLAPPING SUCCESSIVE SHEETS 19 INCHES, AND FASTENED | | WITH 1- INCH ROUND PLASTIC CAP, METAL CAP NAILS OR | | NAILS | | AND TIN-TABS ATTACHED TO A NAILABLE DECK WITH ONE ROW | | IN THE FIELD OF THE SHEET WITH A MAXIMUM FASTENER SPAC- | | ING OF 12 INCHES ON CENTER (305 MM), AND ONE ROW AT THE | | OVERLAPS FASTENED 6 INCHES (152 MM) ON CENTER. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|