2016-07-29 07:38:271ST REVIEW MECHANICAL, ENERGY CONSERVATION- 2016
 PERMIT #16071129
 7/29/16
  
 1) REFER TO SECTION R403.6 AND PROVIDE AC COOLING AND
 HEATING CALCULATIONS FOR THE NEW MINI-SPLIT.
  
 2) REFER TO SECTION M1305.1.4.1 FBC-14 RESIDENTIAL AND
 PROVIDE DETAILS FOR INSTALLATION OF THE CONDENSER PAD
 AND TIE DOWN OF THE UNIT TO THE PAD.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  