Plan Review Notes For Permit 16070877 |
Permit Number |
16070877 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2016-07-28 05:38:46 | 1) SUBMIT A LEGIBLE PLAN FOR REVIEW. THE PLAN SHALL | | CLEARLY SHOW THE LOCATION AND SIZE OF THE ROOF DRAINS | | TO BE REPLACED AND SHOW THE SQUARE FOOT AREA THAT IS | | DRAINING INTO EACH ROOF DRAIN. THE SIZING OF THE ROOF | | DRAINS AND THE DRAIN PIPING SHALL COMPLY WITH 2014 FBC | | - PLUMBING SECS. 1106.2 & 1106.3. SIZING SHALL BE BASED | | ON A RAINFALL RATE OF 5 INCHES PER HOUR. | | 2) PROVIDE A STORM DRAINAGE RISER THAT REFLECTS THE | | SCOPE OF WORK TO BE DONE. | | | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME. | | I CAN BE REACHED AT 561-805-6692 OR [email protected] | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|