2016-08-09 15:45:18ROOFING PLAN REVIEW
 W. P. B. PERMIT: 16070837
 ADD: 309/317 N. ROSEMARY AVE.
 CONT: TBD/ TO BE DETERMINED
 TEL: 305-456-7252
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: SUN. AUGUST 07/2016
 ACTION: DENIED
 .(2) ROOFING APPROVALS WERE SUBMITTED FOR THIS REVIEW.
 CARLISLE MIRASEAL FLUID APPLIED WATERPROOFING MEMBRANE
 NOA 13-0129.22
 CARLISLE CCW-500-R HOT APPLIED LIQUID MEMBRANE NOA
 12-0801.01
 IN BOTH APPROVALS THERE ARE MULTIPLE SUB-SYSTEMS AND
 ASSOCIATED PRESSURES. IN NEITHER REPORT WAS A
 SUB-SYSTEM AND ASSOCIATED PRESSURES INDICATED. ALSO IN
 BOTH REPORTS LIMITATION # 9 IS INDICATED NO ENHANCED
 FASTENING CAN OCCUR. THE PLANS DO NOT INDICATE ROOF TOP
 PRESSURES FOR ZONES 1,2 & 3. PLEASE PROVIDE PRESSURES
 IN VASD SINCE THE PRODUCT APPROVALS ARE IN VASD. 2014
 FBC- B 1603.1.4 WIND DESIGN DATA.
  
 JAMES A. WITMER CBO