2016-08-09 15:41:59 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 16070837 |
| ADD: 309/317 N. ROSEMARY AVE. |
| CONT: TBD/ TO BE DETERMINED |
| TEL: 305-456-7252 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 1ST REVIEW |
| DATE: SUN. AUGUST 07/2016 |
| ACTION: DENIED |
| |
| 1) PLEASE NOTE AN ADDRESSING PLAN REVIEW STOP WILL BE |
| ADDED TO THE PLAN REVIEW CYCLE TO ASSIGN A SITE |
| ADDRESS. IT APPEARS ON THE PALM BCH. COUNTY PROPERTY |
| APPRAISERS WEBSITE THERE ARE 3 ACTUAL PROPERTIES THAT |
| WILL BE MAKING UP THIS SITE. |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION |
| DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION OF THE |
| PROJECT. PLEASE CONTACT MR. ORIO FOR AN SITE ADDRESS. |
| CONTACT: MICHAEL ORIO GIS SUPPORT SPECIALIST/ |
| INFORMATION TECHNOLOGY |
| TEL: 561-494-1040. |
| E-MAIL: [email protected] |
| |
| 2) ART IN PUBLIC PLACES. THE CITY OF WEST PALM BEACH |
| ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES |
| TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH |
| THE PERMIT APPLICATION WAS SUBMITTED AFTER 6/29/2014, |
| AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO |
| OR GREATER THAN $750,000 |
| WILL NEED TO COMPLY WITH THIS ORDINANCE. |
| PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND |
| CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, |
| ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION |
| 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL |
| PROJECT CONSTRUCTION COST. |
| PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE |
| V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND |
| NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO |
| THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE |
| PROJECTS. |
| FOR CONTACT INFORMATION PLEASE CONTACT: |
| MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR |
| 822-1515 E-MAIL: [email protected] |
| |
| 3) THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR |
| THE MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. |
| WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING |
| PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE |
| QUALIFIER AND OWNER AND BRINGS IN THE LISTED |
| SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE |
| QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND |
| LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE |
| FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN |
| LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR |
| EACH PERMIT. |
| |
| ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, EXHAUST |
| HOODS, ANSUL SYSTEMS OR ALTERNATIVE AUTOMATIC |
| FIRE-EXTINGUISHING SYSTEMS , WALK IN COOLERS & |
| FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL |
| TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED |
| SUB-PERMITS, AWNING, CANOPY, FENCE, LANDSCAPE , |
| IRRIGATION, AUGER CAST PILE AND OR FOUNDATION OR |
| STRUCTURE ONLY PERMIT WILL BE SEPARATE REVIEWS AND |
| ASSOCIATED FEES WITH EACH PERMIT. |
| PLEASE LIST AND SUBTRACT THESE LINE ITEMS AND THEIR |
| VALUE FROM THE OVERALL BUILDING VALUE OF $4,088000.00. |
| THE REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF |
| THE BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE |
| BUILDING DOES NOT WANT TO COLLECT TWICE FOR THE VALUE |
| OF THESE SUB-PERMITS NOT COVERED UNDER THE PRIME OR |
| MASTER PERMIT. |
| |
| 4)THIS BUILDING IS A THRESHOLD BUILDING / FL S. S. |
| 553.71(7) ?THRESHOLD BUILDING" MEANING ANY BUILDING |
| WHICH IS GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT, |
| OR WHICH HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS |
| DENIED IN THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 |
| SQ. FT. IN AREA AND AN OCCUPANT CONTENT OF GREATER THAN |
| 500 PERSONS. |
| |
| 4A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING |
| AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL |
| INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A |
| THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION |
| PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL |
| INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING |
| AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR |
| THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE |
| OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE |
| SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT |
| THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE |
| WITH THE PERMITTED DOCUMENTS. |
| |
| 4B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. |
| CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD |
| BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S |
| 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS |
| REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS |
| ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH |
| INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND |
| REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE |
| PLACE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL |
| INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER |
| INFORMATION BEFORE THE PERMIT MAY BE ISSUED. |
| |
| 4C) THRESHOLD BLDG., REQUIRED STATEMENT: W.P.B. |
| AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH |
| ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT |
| OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE |
| BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE |
| PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE |
| FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL |
| AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 |
| FLORIDA STATUTE. |
| |
| 4D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' |
| OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE |
| RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| MEETING THE ABOVE CRITERIA. |
| |
| 4E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR |
| HISTORY FOR THIS TYPE OF CONSTRUCTION. |
| |
| 4F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE |
| REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, |
| PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING |
| ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE |
| APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR |
| PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN |
| COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR |
| THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE |
| IN BLACK & WHITE.. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD |
| BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS |
| CONCERNING SPECIAL INSPECTORS. |
| |
| 4G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, |
| PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT |
| AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING |
| INSTALLATION SHALL BE SUPERVISED, INSPECTED AND |
| CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING |
| DOCUMENTS BY THE CONTRACTOR. |
| |
| 4H) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED |
| TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL |
| BUILDING INSPECTIONS FOR AUDITING OF JOBSITE |
| INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 |
| MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. |
| |
| 4I) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES |
| FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER |
| HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE |
| MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR |
| WALLS AND CEILINGS. |
| |
| 5) PERIMETER FENCING UNDER A SEPARATE PERMIT. PLEASE |
| PROVIDE COMPLIANCE WITH: 2014 FBC-B 3306.5 BARRIERS. |
| BARRIERS SHALL BE A MINIMUM OF 8 FEET (2438 MM) IN |
| HEIGHT AND SHALL BE PLACED ON THE SIDE OF THE WALKWAY |
| NEAREST THE CONSTRUCTION. BARRIERS SHALL EXTEND THE |
| ENTIRE LENGTH OF THE CONSTRUCTION SITE. |
| |
| 6) 2014 FBC0B 3306.2 WALKWAYS. A WALKWAY SHALL BE |
| PROVIDED FOR PEDESTRIAN TRAVEL IN FRONT OF EVERY |
| CONSTRUCTION AND DEMOLITION SITE UNLESS THE APPLICABLE |
| GOVERNING AUTHORITY AUTHORIZES THE SIDEWALK TO BE |
| FENCED OR CLOSED. WALKWAYS SHALL BE OF SUFFICIENT WIDTH |
| TO ACCOMMODATE THE PEDESTRIAN TRAFFIC, BUT IN NO CASE |
| SHALL THEY BE LESS THAN 4 FEET (1219 MM) IN WIDTH. |
| WALKWAYS SHALL BE PROVIDED WITH A DURABLE WALKING |
| SURFACE. WALKWAYS SHALL BE ACCESSIBLE IN ACCORDANCE |
| WITH CHAPTER 11 AND SHALL BE DESIGNED TO SUPPORT ALL |
| IMPOSED LOADS AND IN NO CASE SHALL THE DESIGN LIVE LOAD |
| BE LESS THAN 150 POUNDS PER SQUARE FOOT (PSF). WILL THE |
| WALKWAYS ON THE SOUTH SIDE OF TRINITY PLACE BE CLOSED? |
| |
| 7) 2014 FBC-B 3306.7 COVERED WALKWAYS. COVERED WALKWAYS |
| SHALL HAVE A CLEAR HEIGHT OF NOT LESS THAN 8 FEET (2438 |
| MM) AS MEASURED FROM THE FLOOR SURFACE TO THE CANOPY |
| OVERHEAD. ADEQUATE LIGHTING SHALL BE PROVIDED AT ALL |
| TIMES. COVERED WALKWAYS SHALL BE DESIGNED TO SUPPORT |
| ALL IMPOSED LOADS. IN NO CASE SHALL THE DESIGN LIVE |
| LOAD BE LESS THAN 150 PSF FOR THE ENTIRE STRUCTURE. |
| |
| 8) PLEASE PROVIDE COMPLIANCE WITH: POLLUTION PREVENTION |
| PLAN. 2014 FBC-B 3307.1 PROTECTION REQUIRED. ADJOINING |
| PUBLIC AND PRIVATE PROPERTY SHALL BE PROTECTED FROM |
| DAMAGE DURING CONSTRUCTION, REMODELING AND DEMOLITION |
| WORK. PROVISIONS SHALL BE MADE TO CONTROL WATER RUNOFF |
| AND EROSION DURING CONSTRUCTION OR DEMOLITION |
| ACTIVITIES. THE PERSON MAKING OR CAUSING AN EXCAVATION |
| TO BE MADE SHALL PROVIDE WRITTEN NOTICE TO THE OWNERS |
| OF ADJOINING BUILDINGS ADVISING THEM THAT THE |
| EXCAVATION IS TO BE MADE AND THAT THE ADJOINING |
| BUILDINGS SHOULD BE PROTECTED. SAID NOTIFICATION SHALL |
| BE DELIVERED NOT LESS THAN 10 DAYS PRIOR TO THE |
| SCHEDULED STARTING DATE OF THE EXCAVATION. |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION 109.3.10 IMPACT OF CONSTRUCTION. ALL |
| CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE |
| PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE |
| CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS |
| PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO CONSENT |
| BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS & |
| CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER. |
| THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF |
| DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE |
| STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION |
| ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE |
| WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY |
| REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH |
| ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS |
| OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, |
| CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL |
| DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, |
| DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ. |
| FT. OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A |
| PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED |
| DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS |
| PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A |
| CERTIFICATION FROM A LICENSED ENGINEER SHALL BE |
| SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL |
| OF THE FINAL INSPECTION. |
| |
| 9) PLEASE PROVIDE DETAILS SHOWING HOW COMPLIANCE WITH |
| 2014 FBC-B 3306.9 ADJACENT TO EXCAVATIONS. |
| EVERY EXCAVATION ON A SITE LOCATED 5 FEET (1524 MM) OR |
| LESS FROM THE STREET LOT LINE SHALL BE ENCLOSED WITH A |
| BARRIER NOT LESS THAN 6 FEET (1829 MM) IN HEIGHT. WHERE |
| LOCATED MORE THAN 5 FEET (1524 MM) FROM THE STREET LOT |
| LINE, A BARRIER SHALL BE ERECTED WHERE REQUIRED BY THE |
| BUILDING OFFICIAL. BARRIERS SHALL BE OF ADEQUATE |
| STRENGTH TO RESIST WIND PRESSURE AS SPECIFIED IN |
| CHAPTER 16. SHEET A2.01A & S-1 SHOW PILING RIGHT |
| ADJACENT TO THE PROPERTY LINE SEE COLUMN 1 AND ROW A . |
| |
| 10A) PLEASE PROVIDE DETAILS SHOWING COMPLIANCE WITH |
| 2014 FBC-B 3307.1 PROTECTION REQUIRED. ADJOINING PUBLIC |
| AND PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE |
| DURING CONSTRUCTION AND DEMOLITION WORK. PROTECTION |
| SHALL BE PROVIDED FOR FOOTINGS, FOUNDATIONS, PARTY |
| WALLS, CHIMNEYS, SKYLIGHTS AND ROOFS. WITH THE |
| EXCAVATION AND AUGER CAST PILE HOW WILL THE BUILDING TO |
| THE SOUTH BE PROTECTED FROM SETTLEMENT? |
| SHEET A2.01A & S-1 SHOW PILING RIGHT ADJACENT TO THE |
| PROPERTY LINE SEE COLUMN 1 AND ROW A . |
| |
| 10B) 2014 FBC-B 3307.1 THE PERSON MAKING OR CAUSING AN |
| EXCAVATION TO BE MADE SHALL PROVIDE WRITTEN NOTICE TO |
| THE OWNERS OF ADJOINING BUILDINGS ADVISING THEM THAT |
| THE EXCAVATION IS TO BE MADE AND THAT THE ADJOINING |
| BUILDINGS SHOULD BE PROTECTED. SAID NOTIFICATION SHALL |
| BE DELIVERED NOT LESS THAN 10 DAYS PRIOR TO THE |
| SCHEDULED STARTING DATE OF THE EXCAVATION. SHEET A2.01A |
| & S-1 SHOW PILING RIGHT ADJACENT TO THE PROPERTY LINE |
| SEE COLUMN 1 AND ROW A . |
| |
| 11) WHEN EXCAVATING WILL THE EXCESS SOILS BE STORED ON |
| SITE? 2014 FBC-B 3304.1.2 SURCHARGE. NO FILL OR OTHER |
| SURCHARGE LOADS SHALL BE PLACED ADJACENT TO ANY |
| BUILDING OR STRUCTURE UNLESS SUCH BUILDING OR STRUCTURE |
| IS CAPABLE OF WITHSTANDING THE ADDITIONAL LOADS CAUSED |
| BY THE FILL OR SURCHARGE. EXISTING FOOTINGS OR |
| FOUNDATIONS WHICH CAN BE AFFECTED BY ANY EXCAVATION |
| SHALL BE UNDERPINNED ADEQUATELY OR OTHERWISE PROTECTED |
| AGAINST SETTLEMENT AND SHALL BE PROTECTED AGAINST LATER |
| MOVEMENT. |
| |
| 12) PLEASE DOCUMENT COMPLIANCE WITH: 2014 FBC-B 3313.1 |
| WHERE REQUIRED. AN APPROVED WATER SUPPLY FOR FIRE |
| PROTECTION, EITHER TEMPORARY OR PERMANENT, SHALL BE |
| MADE AVAILABLE AS SOON AS COMBUSTIBLE MATERIAL ARRIVES |
| ON THE SITE. PLEASE PROVIDE WHERE THIS CONNECTION WILL |
| BE MADE. |
| |
| 13) NOTICE: 2014 FBC-B [F] 3311.1 WHERE REQUIRED. IN |
| BUILDINGS REQUIRED TO HAVE STANDPIPES BY SECTION |
| 905.3.1, NOT LESS THAN ONE STANDPIPE SHALL BE PROVIDED |
| FOR USE DURING CONSTRUCTION. SUCH STANDPIPES SHALL BE |
| INSTALLED WHEN THE PROGRESS OF CONSTRUCTION IS NOT MORE |
| THAN 40 FEET (12 192 MM) IN HEIGHT ABOVE THE LOWEST |
| LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS. SUCH STANDPIPE |
| SHALL BE PROVIDED WITH FIRE DEPARTMENT HOSE CONNECTIONS |
| AT ACCESSIBLE LOCATIONS ADJACENT TO USABLE STAIRS. SUCH |
| STANDPIPES SHALL BE EXTENDED AS CONSTRUCTION PROGRESSES |
| TO WITHIN ONE FLOOR OF THE HIGHEST POINT OF |
| CONSTRUCTION HAVING SECURED DECKING OR FLOORING. |
| |
| 14A) 2014 FBC-B [F] 3309.1 WHERE REQUIRED. ALL |
| STRUCTURES UNDER CONSTRUCTION SHALL BE PROVIDED WITH |
| NOT LESS THAN ONE APPROVED PORTABLE FIRE EXTINGUISHER |
| IN ACCORDANCE WITH SECTION 906 AND SIZED FOR NOT LESS |
| THAN ORDINARY HAZARD AS FOLLOWS: |
| 1. AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE |
| COMBUSTIBLE MATERIALS HAVE ACCUMULATED. |
| 2. IN EVERY STORAGE AND CONSTRUCTION SHED. |
| 3. ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE |
| PROVIDED WHERE SPECIAL HAZARDS EXIST, SUCH AS THE |
| STORAGE AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS. |
| |
| 14B) 2014 FBC-B 3309.2 FIRE HAZARDS. THE PROVISIONS OF |
| THIS CODE AND THE FLORIDA FIRE PREVENTION CODE SHALL BE |
| STRICTLY OBSERVED TO SAFEGUARD AGAINST ALL FIRE HAZARDS |
| ATTENDANT UPON CONSTRUCTION OPERATIONS. |
| |
| 15) 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION 109.3.10.1 HURRICANE PROTECTION. IT |
| SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION |
| RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE |
| OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 |
| HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE |
| HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH |
| CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE |
| EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN |
| SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH |
| CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING |
| DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY |
| PERSONS WHO FAILS TO COMPLY TO COMPLY TO REMOVE OR |
| SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS |
| WITHIN 24 HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED |
| SHALL BE SUBJECT TO A FINE NOT TO EXCEED $500.00. IN |
| ADDITION TO THE ABOVE, A LICENSED CONTRACTOR WHO |
| VIOLATES THIS SECTION SHALL BE SUBJECT TO DISCIPLINE |
| PURSUANT TO SECTION 113 OF THIS CHAPTER. |
| |
| 16) SHEET L.S.101: |
| 16A) FIRE PROTECTION GENERAL NOTES # 1 GC TO INSTALL |
| FIRE/ SMOKE DETECTION SYSTEM AS APPLICABLE CODES FOR |
| USE AND OCCUPANCY. PLEASES BE SPECIFIC TO THE 2014 |
| FBC-B. |
| |
| 16B) UNDER THE HEADING CONSTRUCTION TYPE/ OCCUPANCY THE |
| BUILDING CONSTRUCTION TYPE IS LISTED AS A TYPE IIB/ R1 |
| OCCUPANCY TYPE. THE TYPE OF AUTOMATIC FIRE SPRINKLER |
| SYSTEM IS NOT MENTIONED IN THE CONSTRUCTION TYPE NOR IN |
| THE FIRE PROTECTION PLANS. PLEASE DESIGNATE WHAT TYPE |
| OF FIRE SPRINKLER SYSTEM IS DESIGNED FOR THIS BUILDING. |
| NOTE TABLE 503 ONLY ALLOWS 4 STORIES FOR A IIA/ R1 |
| OCCUPANCY. DECLARE THE TYPE OF FIRE SPRINKLERS AND AREA |
| INCREASES TAKEN UNDER FBC-B 506.1 AND EQUATION 5-1 FOR |
| AREA AND SPRINKLER INCREASES. |
| |
| 16C) BUILDING OCCUPANCY CLASSIFICATION HEADING: |
| 16C)(1) PLEASE REVIEW BASEMENT RESIDENTIAL CATEGORY & |
| OCCUPANCY COUNT. SEE FBC-B TABLE 1004.1.2 FUNCTION |
| ACCESSORY STORAGE AREAS AND OCCUPANT LOAD FACTOR 300 |
| GROSS. |
| |
| 16C)(2) PLEASE REVIEW THE GROUND FLOOR AND THE |
| RESIDENTIAL CATEGORY R1. THE LOBBY AREA INCLUDING THE |
| DELI AREA ARE ALL CONSIDERED A BUSINESS OCCUPANCY @ 100 |
| SQ. FT./ OCCUPANT. SEE FBC-B TABLE 1004.1.2. UPDATE |
| PLANS. |
| |
| 16 C)(3) PLEASE PROVIDE THE TOTAL SQ. FT. OF THE |
| BUILDING AREA AND REVISED TOTAL OCCUPANT LOAD FOR THE |
| BUILDING. |
| |
| 16D) PLEASE UPDATE BOTH EGRESS REQUIREMENTS AND FIXTURE |
| COUNT SINCE THE OCCUPANCY LOADS WILL BE INCREASED. |
| FBC-B TABLE 1004.1.2. |
| |
| 16E) THE PLANS INDICATE THIS IS A R1 OCCUPANCY BUT |
| PLEASE CONFIRM THAT THE UNITS THEMSELVES ARE TO BE |
| CONSIDERED EITHER SLEEPING UNITS OR DWELLING UNITS. THE |
| PLANS ARE VAGUE AS TO IF THERE IS TO BE A KITCHEN OR |
| KITCHENETTE. IF THE SUITES ARE TO BE CONSIDERED A |
| DWELLING UNIT THEN COMPLIANCE WITH THE FOLLOWING 3 CODE |
| SECTIONS WOULD BE REQUIRED FOR BUILDING TYPE IIA/ R1- |
| IF (DWELLING UNIT). |
| FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO |
| HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES |
| TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS |
| LISTED UNDER EACH OF THE STANDARDS FOR A 8 INCH |
| CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: |
| PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: |
| |
| 16E)(1) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| |
| 16E)(2) FBC-B 2014 1207.2 AIR-BORNE SOUND. |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. |
| |
| 16E)(3) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. |
| INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| |
| FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| |
| 16F) PLEASE REVIEW THE TRAVEL DISTANCE FROM THE |
| FURTHEST POINT IN THE LAUNDRY. THIS POINT IS TO BE |
| TAKEN FROM THE FURTHEST POINT IN THE LAUNDRY ROOM AND |
| THEN THE TRAVEL ROUTE TO BE TAKEN 1 FOOT FROM THE WALL |
| LINE FURNITURE OR EQUIPMENT TO THE EXIT DOOR WAY. |
| COMMON PATH OF TRAVEL, FBC-B TABLE 1014.3. STORAGE |
| OCCUPANCY < 30 OCCUPANCY ALLOWS FOR 100 FT. TRAVEL |
| DISTANCE/ SPRINKLERED BUILDING. |
| |
| 16F) THE LIFE SAFETY SHEET IS SILENT AS TO THE FIRE |
| RATING REQUIREMENTS FOUND IN FBC-B TABLE 601 & 602. |
| |
| 704.2 COLUMN PROTECTION. WHERE COLUMNS ARE REQUIRED TO |
| HAVE PROTECTION TO BE FIRE-RESISTANCE RATED, THE ENTIRE |
| COLUMN SHALL BE PROVIDED INDIVIDUAL ENCASEMENT |
| PROTECTION BY PROTECTING IT ON ALL SIDES FOR THE FULL |
| COLUMN LENGTH, INCLUDING CONNECTIONS TO OTHER |
| STRUCTURAL MEMBERS, WITH MATERIALS HAVING THE REQUIRED |
| FIRE-RESISTANCE RATING. WHERE THE COLUMN EXTENDS |
| THROUGH A CEILING, THE ENCASEMENT PROTECTION SHALL BE |
| CONTINUOUS FROM THE TOP OF THE FOUNDATION OR |
| FLOOR/CEILING ASSEMBLY BELOW THROUGH THE CEILING SPACE |
| TO THE TOP OF THE COLUMN. |
| |
| 704.3 PROTECTION OF THE PRIMARY STRUCTURAL FRAME OTHER |
| THAN COLUMNS. MEMBERS OF THE PRIMARY STRUCTURAL FRAME |
| OTHER THAN COLUMNS THAT ARE REQUIRED TO HAVE PROTECTION |
| TO ACHIEVE A FIRE-RESISTANCE RATING AND SUPPORT MORE |
| THAN TWO FLOORS OR ONE FLOOR AND ROOF, OR SUPPORT A |
| LOAD-BEARING WALL OR A NONLOAD-BEARING WALL MORE THAN |
| TWO STORIES HIGH, SHALL BE PROVIDED INDIVIDUAL |
| ENCASEMENT PROTECTION BY PROTECTING THEM ON ALL SIDES |
| FOR THE FULL LENGTH, INCLUDING CONNECTIONS TO OTHER |
| STRUCTURAL MEMBERS, WITH MATERIALS HAVING THE REQUIRED |
| FIRE-RESISTANCE RATING. |
| |
| 704.4 PROTECTION OF SECONDARY MEMBERS. SECONDARY |
| MEMBERS THAT ARE REQUIRED TO HAVE A FIRE-RESISTANCE |
| RATING SHALL BE PROTECTED BY INDIVIDUAL ENCASEMENT |
| PROTECTION, BY THE MEMBRANE OR CEILING OF A HORIZONTAL |
| ASSEMBLY IN ACCORDANCE WITH SECTION 711, OR BY A |
| COMBINATION OF BOTH. |
| |
| 17) SHEET A2.01B BASEMENT LEVEL; |
| 17A) THE LAUNDRY TERMINATION ROOM, LAUNDRY ROOM ARE IN |
| THE SAME ROOM. THE PLANS DO NOT INDICATE WHERE THE |
| LAUNDRY TERMINATION ROOM ENDS AND WHERE THE CORRIDOR |
| BEGINS. THE PLANS DO NOT INDICATE WHERE THE DIRTY |
| LAUNDRY CARTS ARE GOING TO BE STORED EITHER. THE PLANS |
| ALSO SHOW THE SAME LAUNDRY TERMINATION ROOM AS THE |
| LAUNDRY ROOM. THE PLANS ARE SILENT AS TO WHERE THE |
| CLEAN LINENS ARE TO BE STORED, NOR DO THE PLANS |
| INDICATE WHAT WILL BE STORED IN THE BASEMENT LEVEL |
| STORAGE ROOM. THIS WHOLE AREA NEEDS TO SHOW HOW |
| COMPLIANCE WITH ALL THESE CONCERNS ARE GOING TO BE |
| ADDRESSED. |
| PLEASE SEE FBC-B 1014.2 EGRESS THROUGH INTERVENING |
| SPACES. EGRESS THROUGH INTERVENING SPACES SHALL COMPLY |
| WITH THIS SECTION. 4. EGRESS SHALL NOT PASS THROUGH |
| STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR |
| PURPOSES. |
| |
| 17B) 2014 FBC-B 713.13.4 TERMINATION ROOM. REFUSE, |
| RECYCLING, AND LAUNDRY CHUTES SHALL DISCHARGE INTO AN |
| ENCLOSED ROOM SEPARATED FROM THE REMAINDER OF THE |
| BUILDING BY FIRE BARRIERS CONSTRUCTED IN ACCORDANCE |
| WITH SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED |
| IN ACCORDANCE WITH SECTION 711, OR BOTH. |
| |
| 17C) 713.13.4 TERMINATION ROOM. OPENINGS INTO THE |
| TERMINATION ROOM SHALL BE PROTECTED BY OPENING |
| PROTECTIVES HAVING A FIRE PROTECTION RATING EQUAL TO |
| THE PROTECTION REQUIRED FOR THE SHAFT ENCLOSURE. 2 HOUR |
| SHAFT ENCLOSURES REQUIRE 1 ? HOUR OPENING PROTECTIVES |
| TABLE 716.5. |
| |
| 17D) 713.13.4 TERMINATION ROOM. DOORS SHALL BE SELF- OR |
| AUTOMATIC-CLOSING UPON THE DETECTION OF SMOKE IN |
| ACCORDANCE WITH SECTION 716.5.9.3. DOOR NOT SHOWN ON |
| THE PLANS. |
| |
| 17E)LAUNDRY CHUTE DETAILS. SEE SHEET A6.05 THESE |
| DETAILS SEEM TO BE TAKEN FROM A DETAIL SHEET PAGE 2 AND |
| 3 WHERE THEY ARE NOTE SHOWN. NOTES 1,2,3,8,9,12 & 13. |
| 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. |
| |
| 17F) PLEASE NOTE IN THIS DETAIL THE 2 HOUR FIRE RATED |
| SHAFT IS NOT SHOWN. IT IS NOT CLEAR IF THE SHAFT |
| CONTINUES DOWN INTO THE TERMINATION ROOM AND THE 1 ? |
| HOUR PROTECTIVE IS THE NOTE(3) DISCHARGE DOOR. THE |
| PLANS DO NOT INDICATE ANY FIRE RATING. |
| |
| 17G)(1) THE PLANS ARE NOT CLEAR WITH NOTE 7 AND NOTE 12 |
| IF THESE ARE A SEPARATE ITEM NOT DEALING WITH THE |
| REQUIREMENTS FOR 713.13.6 AUTOMATIC SPRINKLER SYSTEM. |
| AN APPROVED AUTOMATIC SPRINKLER SYSTEM SHALL BE |
| INSTALLED IN ACCORDANCE WITH SECTION 903.2.11.2. |
| 17G)(2) FBC-B 903.2.11.2 RUBBISH AND LINEN CHUTES. AN |
| AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED AT THE |
| TOP OF RUBBISH AND LINEN CHUTES AND IN THEIR TERMINAL |
| ROOMS. CHUTES SHALL HAVE ADDITIONAL SPRINKLER HEADS |
| INSTALLED AT ALTERNATE FLOORS AND AT THE LOWEST INTAKE. |
| WHERE A RUBBISH CHUTE EXTENDS THROUGH A BUILDING MORE |
| THAN ONE FLOOR BELOW THE LOWEST INTAKE, THE EXTENSION |
| SHALL HAVE SPRINKLERS INSTALLED THAT ARE RECESSED FROM |
| THE DROP AREA OF THE CHUTE AND PROTECTED FROM FREEZING |
| IN ACCORDANCE WITH SECTION 903.3.1.1. SUCH SPRINKLERS |
| SHALL BE INSTALLED AT ALTERNATE FLOORS, BEGINNING WITH |
| THE SECOND LEVEL BELOW THE LAST INTAKE AND ENDING WITH |
| THE FLOOR ABOVE THE DISCHARGE. CHUTE SPRINKLERS SHALL |
| BE ACCESSIBLE FOR SERVICING. |
| |
| 17H) THE SOILED LINEN WHERE TO STORE? VERSES THE CLEAN |
| LINEN ROOMS. TABLE 509 INCIDENTAL USES. |
| |
| 17I) INTERIOR WALLS DO NOT HAVE IDENTIFICATION TAGS |
| IDENTIFYING WALL TYPES. 107.3.5.1.1 MINIMUM COMMERCIAL |
| PLAN REVIEW REQUIREMENTS. (4) FIRE RESISTANT |
| CONSTRUCTION. |
| |
| 18) SHEET A2.01A. GROUND FLOOR; |
| 18A) THIS FLOOR DOES HAVE WALL IDENTIFICATION TAGS. |
| WALL TYPES ARE FOUND ON SHEET A8.03. |
| THERE ARE (2) ISSUES WITH THE WALL TYPES FOUND ON THIS |
| SHEET. |
| |
| 18A)(1) FOR THE METAL STUD FIRE RATED WALLS THESE WALL |
| TYPES LIST A UL FIRE RATING AND HOUR RATING. WHAT THE |
| DESIGNER OF RECORD DIDN?T INCLUDE WAS A SHEET THAT |
| GIVES EACH OF THE WALL ASSEMBLY BREAK DOWNS AS IN THE |
| UL LISTING BOOK. THE INSPECTORS NEED THIS INFORMATION |
| TO VERIFY THE WALLS WERE BUILT CORRECTLY ACCORDING TO |
| THE WALL ASSEMBLY AS TESTED. FBC-B 703.2 |
| FIRE-RESISTANCE RATINGS. |
| |
| 18B) PLEASE SHOW THE MASONRY WALLS 4 INCH / 2 HR. RATED |
| WITH THE CENTER CAVITY. THE DESIGN # 906 IS FOR 6INCH |
| BLOCK EITHER HOLLOW OR SOLID BUT NOT FOR A 4 INCH BLOCK |
| WALL. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. FBC-B |
| TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (INCHES) OF |
| BEARING OR NONBEARING CONCRETE MASONRY WALLS. |
| |
| 18C) THE L. S. SHEET NOR THE GROUND FLOOR SHOW THE |
| PARKING GARAGE AS DESIGNED OPEN OR ENCLOSED. THE PLANS |
| DO NOT APPEAR TO MAKE THE REQUIREMENTS FOR AN OPEN |
| PARKING GARAGE UNDER SECTION FBC-B 406.5.2 AND WILL |
| NEED TO MEET THE REQUIREMENTS FOR 406.6.2 VENTILATION |
| AND 406.6.3 AUTOMATIC SPRINKLER SYSTEM. |
| THE M1.1 SHEET ALSO DOES NOT SHOW ANY MECHANICAL |
| EQUIPMENT FOR MECHANICAL EQUIPMENT. THERE SEAMS TO BE A |
| OPENING MISSING IN THE GARAGE CEILING (HIDDEN DASHED |
| LINE) ON THE GRID LINE C/ 5 THAT GOES VERTICALLY |
| THROUGH TO THE ROOF. IF THE DESIGNERS INTENT IS O TAKE |
| CREDIT FOR THE 3 VERTICAL OPENS IN THE CEILING AS WELL |
| AS THE ONE ON GRID LINE C/5 AS EQUAL TO CROSS |
| VENTILATION FOR AN OPEN PARKING GARAGE, THEN |
| CALCULATIONS WILL BE NEEDED TO PROVIDE CODE COMPLIANCE |
| UNDER SECTION 104.11 ALTERNATE MATERIALS, DESIGN AND |
| METHODS OF CONSTRUCTION AND EQUIPMENT. A LETTER TO THE |
| BUILDING OFFICIAL WOULD ALSO NEED TO FOLLOW ASKING THIS |
| DESIGN TO BE REVIEWED UNDER 104.11 ALTERNATE MATERIALS, |
| DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT. |
| |
| 104.11.1 RESEARCH REPORTS. SUPPORTING DATA, WHERE |
| NECESSARY TO ASSIST IN THE APPROVAL OF MATERIALS OR |
| ASSEMBLIES NOT SPECIFICALLY PROVIDED FOR IN THIS CODE, |
| SHALL CONSIST OF VALID RESEARCH REPORTS FROM APPROVED |
| SOURCES. |
| |
| 18D) THE NORTH PROPERTY LINE THERE IS A GATE MARKED # |
| 3, THIS MOTORIZED GATE SHOWS IN THE OPEN POSITION ON |
| BOTH THE GRADE PLAN AND LIFE SAFETY SHEET LS1.01. WHEN |
| YOU LOOK AT THE ELEVATION SHEET A3.04 WHEN THE GATE IS |
| IN THE CLOSED POSITION IT BLOCKS THE MEANS OF EGRESS |
| FROM THE NORTH STAIR TOWER. |
| |
| 2014 FBC-B 1008.2 GATES. GATES SERVING THE MEANS OF |
| EGRESS SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF |
| THIS SECTION. GATES USED AS A COMPONENT IN A MEANS OF |
| EGRESS SHALL CONFORM TO THE APPLICABLE REQUIREMENTS FOR |
| DOORS. |
| 2014 FBC-B 1008.1.2 DOOR SWING. EXCEPTION 9. IN OTHER |
| THAN GROUP H OCCUPANCIES, MANUALLY OPERATED HORIZONTAL |
| SLIDING DOORS ARE PERMITTED IN A MEANS OF EGRESS FROM |
| SPACES WITH AN OCCUPANT LOAD OF 10 OR LESS. |
| |
| DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL |
| WHERE SERVING A ROOM OR AREA CONTAINING AN OCCUPANT |
| LOAD OF 50 OR MORE PERSONS OR A GROUP H OCCUPANCY. |
| |
| 18E) THIS SAME AREA THERE IS A DELIVERY SERVICE AREA 10 |
| FT. X 25 FT. PLEASE SHOW WHERE THE EXIT DISCHARGE PATH |
| OF EGRESS WILL OCCUR SINCE THE DELIVERY LANE IS 10 FEET |
| WIDE AND FROM THE BUILDING TO THE PROPERTY LINE |
| THERE IS ONLY 11 FEET . |
| |
| 1027.4.1 WIDTH. THE MINIMUM WIDTH OF EGRESS COURTS |
| SHALL BE DETERMINED AS SPECIFIED IN SECTION 1005.1, BUT |
| SUCH WIDTH SHALL NOT BE LESS THAN 44 INCHES (1118 MM), |
| EXCEPT AS SPECIFIED HEREIN. EGRESS COURTS SERVING GROUP |
| R- 3 AND U OCCUPANCIES SHALL NOT BE LESS THAN 36 INCHES |
| (914 MM) IN WIDTH. THE REQUIRED WIDTH OF EGRESS COURTS |
| SHALL BE UNOBSTRUCTED TO A HEIGHT OF 7 FEET (2134 MM). |
| |
| 1027.4.2 CONSTRUCTION AND OPENINGS. WHERE AN EGRESS |
| COURT SERVING A BUILDING OR PORTION THEREOF IS LESS |
| THAN 10 FEET (3048 MM) IN WIDTH, THE EGRESS COURT WALLS |
| SHALL HAVE NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED |
| CONSTRUCTION FOR A DISTANCE OF 10 FEET (3048 MM) ABOVE |
| THE FLOOR OF THE COURT. OPENINGS WITHIN SUCH WALLS |
| SHALL BE PROTECTED BY OPENING PROTECTIVES HAVING A FIRE |
| PROTECTION RATING OF NOT LESS THAN 3/4 HOUR. |
| |
| 18F) THE SOUTH STAIRWAY THE WALKWAY IS NOT DIMENSIONED |
| AS TO WIDTH. PLEASE NOTE THE STORAGE DOORS 121 BEING 3 |
| FOOT WIDE DOORS. SEE SECTION 1005.7.1 DOORS. DOORS IN |
| ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY |
| MORE THAN ONE-HALF THE REQUIRED EGRESS PATH. |
| |
| 18G) THE GATE # 101 IS A OUT SWING GATE AND HAS LESS |
| THAN 18 INCHES ON THE PULL SIDE OF THE LATCH. SEE 2014 |
| ACCESS. CODE 404.2.4 MANEUVERING CLEARANCES. |
| |
| 18H) PLEASE REVIEW THE ENTRY INTO THE PARKING GARAGE |
| SOUTH SIDE OF THE BUILDING THERE IS A MOTORIZED GATE. |
| THE LOCATION OF THE GATE MOTOR WILL BLOCK ACCESS FOR |
| PEOPLE EXITING THE GARAGE TO THE PUBLIC WAY, THE GATE |
| IN THE CLOSED POSITION WOULD STILL HAVE TO HAVE A FRAME |
| WORK OVER THIS EXIT DISCHARGE. WHEN THE GATE IS IN THE |
| OPEN POSITION THE GATE FRAMEWORK WOULD EXTEND PAST THE |
| PROPERTY LINE. THE SECOND ISSUE IS FOR THIS WALKWAY TO |
| BE ACCESSIBLE THERE CANNOT BE A STEP FROM THE GARAGE UP |
| TO THE LANDING FOR THE VERTICAL EXIT. |
| THIS IS THE ONLY EXIT OUT OF THE GARAGE. 2014 |
| FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF EGRESS |
| SHALL COMPLY WITH SECTION 1003.2.13 OF THE |
| INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 |
| SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL |
| BUILDING CODE (2003 EDITION). |
| |
| 18I) THERE SEEMS TO BE A DISCREPANCY IN PLANS WITH THE |
| LOCATION OF GATE # 101. PLEASE ALSO SEE THE SOUTH |
| ELEVATION A4.03 107.2.1.3 ADDITIONAL INFORMATION IS |
| REQUIRED. |
| |
| 18J) GATE # 103 SWINGS BACK IN THE FLOW OF EGRESS. |
| FBC-B 1008.2 GATES. GATES SERVING THE MEANS OF EGRESS |
| SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF THIS |
| SECTION. GATES USED AS A COMPONENT IN A MEANS OF EGRESS |
| SHALL CONFORM TO THE APPLICABLE REQUIREMENTS FOR DOORS. |
| 1008.1.2 DOOR SWING. DOORS SHALL SWING IN THE DIRECTION |
| OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA |
| CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR A |
| GROUP H OCCUPANCY. |
| |
| 18K) THE PLANS DO NOT INDICATE A CUT SECTION THROUGH |
| THE FRONT COUNTER FOR REGISTERING. PLEASE SHOW HOW |
| COMPLIANCE WITH ACCESS. CODE 904.3.2 COUNTER & 904.4 |
| SALES AND SERVICE COUNTERS. , 904.3.3 CHECK WRITING |
| SURFACES & WHERE PROVIDED, CHECK WRITING SURFACES SHALL |
| COMPLY WITH 902.3. |
| |
| 19) SHEET A2.02 THE SECOND FLOOR LEVEL: |
| 19A) THE ACCESSIBLE SUITE # 2 IS MISSING THE 18 INCHES |
| ON THE INTERIOR SIDE OF THE MAIN ENTRY DOOR. SEE 2014 |
| ACCESS. CODE 404.2.4. |
| |
| 19B) THE ACCESSIBLE SUITE SHOWS A DETAIL # 1/ A7.2 |
| SHOULD INCLUDE THE KITCHENETTE UNIT SINCE IT IS WITHIN |
| THE DETAIL, NOT INCLUDED. PLEASE PROVIDE ELEVATION |
| DETAILS FOR THE KITCHENETTE AREA AND COMPLIANCE WITH; |
| ACCESS. CODE 606.3 HEIGHT. LAVATORIES AND SINKS SHALL |
| BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR |
| COUNTER SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE |
| FINISH FLOOR OR GROUND. |
| 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING |
| WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE |
| AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| |
| 19C) THE ACCESSIBLE SUITE DOES NOT INDICATE HOW |
| COMPLIANCE WITH 242.2 ACCESSIBLE SWIMMING POOLS ARE |
| GOING TO BE ACHIEVED. SEE EXCEPTION 1 REQUIREMENT. |
| WHERE A SWIMMING POOL HAS LESS THAN 300 LINEAR FEET OF |
| SWIMMING POOL WALL, NO MORE THAN ONE ACCESSIBLE MEANS |
| OF ENTRY SHALL BE REQUIRED PROVIDED THAT THE ACCESSIBLE |
| MEANS OF ENTRY IS A SWIMMING POOL LIFT COMPLYING WITH |
| 1009.2 OR SLOPED ENTRY COMPLYING WITH 1009.3. |
| |
| 19D) THIS IS GOING TO BE A COMMENT FOR ALL UNITS NOT |
| JUST THE ACCESSIBLE UNIT. THE PLANS SHOW SLIDING GLASS |
| DOORS THAT LED FROM WITHIN THE SUITE OUT TO THE TERRACE |
| DECK. THE COMPLETE OPENING BEING 14 FOOT 10 INCHES WIDE |
| DIVIDE BY 3 EQUALS OR EACH PANEL 4 FT. 11 ? INCHES |
| APPROXIMATELY. THIS SIZE DOOR CAN BE USED IN A MEANS OF |
| EGRESS WHEN THE OCCUPANT LOAD IS 10 OR LESS, 1008.1.2 |
| EXCEP. #9. THE DOOR IS 19/32 IN. LAMINATED GLASS. |
| 2014 FBC-B 1008.1.3 DOOR OPENING FORCE. THE FORCE FOR |
| PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS, |
| OTHER THAN FIRE DOORS, SHALL NOT EXCEED 5 POUNDS (22 |
| N). FOR OTHER SWINGING DOORS, AS WELL AS SLIDING AND |
| FOLDING DOORS, THE DOOR LATCH SHALL RELEASE WHEN |
| SUBJECTED TO A 15-POUND (67 N) FORCE. THE DOOR SHALL BE |
| SET IN MOTION WHEN SUBJECTED TO A 30-POUND (133 N) |
| FORCE. THE DOOR SHALL SWING TO A FULL-OPEN POSITION |
| WHEN SUBJECTED TO A 15-POUND (67 N) FORCE. |
| FOR THE ACCESSIBLE UNIT THE OPENING FORCE FOR THE |
| SLIDING GLASS DOOR WILL BE FBC-ACCESS. CODE 404.2.9 |
| DOOR AND GATE OPENING FORCE. FIRE DOORS SHALL HAVE A |
| MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE |
| ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR |
| PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL |
| BE AS FOLLOWS: 2. SLIDING OR FOLDING DOORS: 5 POUNDS |
| (22.2 N) MAXIMUM. |
| |
| 19E) THE OTHER ISSUE COMMON TO ALL UNITS WITH THE |
| SLIDING DOOR TO THE POOL DECK IS: 404.2.7 DOOR AND GATE |
| HARDWARE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER |
| OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH |
| 309.4. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 |
| INCHES (865 MM) MINIMUM AND 48 INCHES (1220 MM) MAXIMUM |
| ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS |
| ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE |
| SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. |
| EXCEPTIONS: 2. ACCESS GATES IN BARRIER WALLS AND FENCES |
| PROTECTING POOLS, SPAS, AND HOT TUBS SHALL BE PERMITTED |
| TO HAVE OPERABLE PARTS OF THE RELEASE OF LATCH ON |
| SELF-LATCHING DEVICES AT 54 INCHES (1370 MM) MAXIMUM |
| ABOVE THE FINISH FLOOR OR GROUND PROVIDED THE |
| SELF-LATCHING DEVICES ARE NOT ALSO SELF-LOCKING DEVICES |
| AND OPERATED BY MEANS OF A KEY, ELECTRONIC OPENER, OR |
| INTEGRAL COMBINATION LOCK. |
| |
| THE DOORS ARE TO BE SELF-CLOSING AND SELF-LATCHING. |
| FBC-B 454.1.3.1.9 ACCESS THROUGH THE BARRIER OR FENCE |
| FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS, MOTEL |
| ROOMS AND HOTEL ROOMS, SHALL BE THROUGH SELF-CLOSING, |
| SELF-LATCHING LOCKABLE GATES OF 48 INCH (1219 MM) |
| MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH THE LATCH |
| LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM THE |
| BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) BELOW |
| THE TOP OF THE GATE ON THE POOL SIDE. IF THE |
| SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING |
| AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR |
| INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF |
| SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864 |
| MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED |
| FLOOR OR GROUND. |
| |
| 19F) PLEASE NOTE THE SLIDING GLASS DOOR, THE THRESHOLD |
| INDICATES ONLY TO BE ? INCH HIGH. 404.2.5 THRESHOLDS. |
| THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH |
| (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN |
| LEVEL AT DOORWAYS SHALL COMPLY WITH ACCESS. CODE 302 |
| AND 303. HOW WILL WATER INTRUSION BE HANDLED IN A |
| HURRICANE? |
| |
| 19G) COMMON COMMENT FOR ALL FLOORS. THE SHAFT WALLS FOR |
| THE LAUNDRY CHUTE DO NOT HAVE WALL IDENTIFICATION TAGS. |
| FBC-B 713.4 FIRE-RESISTANCE RATING. SHAFT ENCLOSURES |
| SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 |
| HOURS WHERE CONNECTING FOUR STORIES OR MORE, AND NOT |
| LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR |
| STORIES. |
| |
| 19H) COMMON COMMENT FOR ALL FLOORS. PLEASE SEE DOOR # 8 |
| TO THE HOSE KEEPING ROOM IN THE DOOR SCHEDULE MISSING |
| THE FIRE RATING. FBC-B 713.13.3 REFUSE, RECYCLING AND |
| LAUNDRY CHUTE ACCESS ROOMS. |
| ACCESS OPENINGS FOR REFUSE, RECYCLING AND LAUNDRY |
| CHUTES SHALL BE LOCATED IN ROOMS OR COMPARTMENTS |
| ENCLOSED BY NOT LESS THAN 1-HOUR FIRE BARRIERS |
| CONSTRUCTED IN ACCORDANCE WITH SECTION 707 OR |
| HORIZONTAL ASSEMBLIES CONSTRUCTED IN ACCORDANCE WITH |
| SECTION 711, OR BOTH. OPENINGS INTO THE ACCESS ROOMS |
| SHALL BE PROTECTED BY OPENING PROTECTIVES HAVING A FIRE |
| PROTECTION RATING OF NOT LESS THAN 3/4 HOUR. DOORS |
| SHALL BE SELF- OR AUTOMATIC-CLOSING UPON THE DETECTION |
| OF SMOKE IN ACCORDANCE WITH SECTION 716.5.9.3. |
| |
| 20) THE ACCESSIBLE SUITE SHOWS A DETAIL # 1/ A7.2. THE |
| ACCESSIBLE BATHROOM: |
| 20A) THIS SHEET STATES MANY TIMES ON THE SHEET THIS IS |
| A ADA COMPLIANT. PLEASE NOTE THE DESIGN MAYBE ADA |
| COMPLIANT BUT THE STATE OF FLORIDA USES THE 2014 |
| FLORIDA ACCESSIBILITY CODE THAT HAS BEEN APPROVED BY |
| THE DEPARTMENT OF JUSTICE. THE FLORIDA ACCESSIBILITY |
| CODE IS A MORE STRINGENT CODE THAN THE ADA. PLEASE |
| REVIEW THE CLEAR FLOOR SPACE REQUIRED FOR THE WATER |
| CLOSET. |
| 2014 FBC-ACCESS. CODE 604.3.2 OVERLAP. THE REQUIRED |
| CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO |
| OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, |
| DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, |
| SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND |
| CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE TURNING |
| SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE |
| LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. |
| 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE |
| 60 INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM |
| THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED |
| PERPENDICULAR FROM THE REAR WALL. |
| |
| 20B) DETAIL D NOTE 11 INDICATES BACKING IS REQUIRED FOR |
| ADAPTABLE BATHROOMS. TABLE 224.2 WILL REQUIRE AT LEAST |
| ONE GUESTROOM/ BATHROOM TO COMPLY WITH GUEST ROOM WITH |
| MOBILITY FEATURES, 609.8 STRUCTURAL STRENGTH. ALLOWABLE |
| STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN |
| A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED |
| AT ANY POINT ON THE GRAB BAR, FASTENER, MOUNTING |
| DEVICE, OR SUPPORTING STRUCTURE. |
| |
| 20C) PLEASE NOTE ON THE GRAB BAR DIMENSIONS THE 2014 |
| FBC-ACCESSIBILITY CODE TAKES THE DIMENSIONS FROM THE |
| TOP OF THE GRASPING SURFACE NOT CENTERLINE. 609.4. |
| |
| 20D) TOWEL BARS ARE NOT DIMENSIONED BUT SHOULD BE IN |
| THE REACH RANGES FOR EITHER FORWARD OR SIDE APPROACH |
| SEE FBC-ACCESS. CODE 308.1. |
| 20E) COAT HOOKS AND SHELVING TO COMPLY WITH 604.2. |
| |
| 20F) THE STEAM SHOWER IN THE ACCESSIBLE GUEST UNIT WILL |
| ALSO NEED TO SHOW COMPLIANCE WITH THE 2014 FBC-ACCESS. |
| CODE ; |
| 20F)(1) 612.2 BENCH. WHERE SEATING IS PROVIDED IN |
| SAUNAS AND STEAM ROOMS, AT LEAST ONE BENCH SHALL COMPLY |
| WITH 903. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR |
| SPACE REQUIRED BY 903.2. EXCEPTION: A READILY REMOVABLE |
| BENCH SHALL BE PERMITTED TO OBSTRUCT THE TURNING SPACE |
| REQUIRED BY 612.3 AND THE CLEAR FLOOR OR GROUND SPACE |
| REQUIRED BY 903.2. |
| |
| 20F)(2) 612.3 TURNING SPACE. A TURNING SPACE COMPLYING |
| WITH 304 SHALL BE PROVIDED WITHIN SAUNAS AND STEAM |
| ROOMS. |
| |
| 21) SHEET A2.07 THESE COMMENTS WILL BE COMMON TO ALL |
| FLOORS 2-5; |
| 21A) NOTE # 14 INDICATES THE USE OF TREX DECK TERRACE |
| AND CEILING. THERE IS NO PRODUCT INFORMATION FOR THE |
| TREX DECK SYSTEM. PLEASE PROVIDE THE MANUFACTURERS |
| SPECIFICATION, IF THIS IS A COMBUSTIBLE PRODUCT AND IF |
| SO THE FLAME SPREAD AND TO WHAT STANDARD THE PRODUCT |
| WAS TESTED TOO? SEE FBC-B SECTION 603 COMBUSTIBLE |
| MATERIAL IN TYPE I AND II CONSTRUCTION. 603.1 ALLOWABLE |
| MATERIALS. |
| |
| 21B) THERE ARE NO PLANS FOR THE TREX DECK DROP CEILING |
| ASSEMBLY. TYPE OF FRAMING, MATERIAL, SPACING, SIZE OF |
| FRAMING MEMBERS, ANCHORAGE TO THE DECK ABOVE IF STIFF |
| BACKS ARE REQUIRED. 107.3.5 MINIMUM PLAN REVIEW |
| CRITERIA FOR BUILDINGS. 107.3.5.1 COMMERCIAL BUILDINGS: |
| DROPPED EXTERIOR CEILING ASSEMBLIES. |
| |
| 21C) DETAILS 3 & 4 BOTH INDICATE THE USE OF INSULATION |
| IN BOTH THE MECHANICAL PLENUM AS WELL AS THE DROPPED |
| CEILING WITHIN THE TYPICAL SUITE. THE PLANS DOES NOT |
| DECLARE WHAT TYPE OF INSULATION IS GOING TO BE |
| INSTALLED? IS THIS INSULATION GOING TO BE FOR BOTH |
| SOUND AND THERMAL VALUES? SEE FBC-B 720.1 & 720.2. |
| |
| 21D) DETAILS 3 & 4 WITHIN THE SUITE SHOW A DROPPED |
| CEILING ASSEMBLY, FASTENED TO THE CONCRETE DECK ABOVE |
| AS WELL AS A DROPPED CEILING ASSEMBLY WITH WHAT MAYBE A |
| LIGHT TROUGH. THE INSULATION ABOVE WOULD STILL BE |
| WITHIN THE ROOM PROPER. PLEASE PROVIDE ADDITIONAL |
| DETAILS AS TO THE TYPE OF FRAMING MATERIALS, ANCHORAGE |
| TO THE DECK ABOVE, SIZE OF FRAMING MEMBERS, SPACING OF |
| FRAMING MEMBERS THE TYPE OF INSULATION, THE THICKNESS |
| AND TYPE OF FINISH MATERIAL FOR THE DROPPED CEILING. . |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| 107.3.5.1 COMMERCIAL BUILDINGS: DROPPED EXTERIOR |
| CEILING ASSEMBLIES. |
| FBC-B 720.3 EXPOSED INSTALLATION. INSULATING MATERIALS, |
| WHERE EXPOSED AS INSTALLED IN BUILDINGS OF ANY TYPE OF |
| CONSTRUCTION, SHALL HAVE A FLAME SPREAD INDEX OF NOT |
| MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE |
| THAN 450. |
| FBC-B 803.11.2 SET-OUT CONSTRUCTION. WHERE WALLS AND |
| CEILINGS ARE REQUIRED TO BE OF FIRE-RESISTANCE-RATED OR |
| NONCOMBUSTIBLE CONSTRUCTION AND WALLS ARE SET OUT OR |
| CEILINGS ARE DROPPED DISTANCES GREATER THAN SPECIFIED |
| IN SECTION 803.11.1, CLASS A FINISH MATERIALS, IN |
| ACCORDANCE WITH SECTION 803.1.1 OR 803.1.2, SHALL BE |
| USED. |
| |
| 21E) PLEASE NOTE THE PLANS DO NOT ADDRESS THE FRAMING |
| MEMBERS FOR THE POOL DECK. SHEET S-13 SECTION SHOWS |
| 3X12?S AT 16 INCHES ON CENTER. THIS BUILDING IS |
| CLASSIFIED AS A BUILDING TYPE IIA. |
| |
| FBC-B SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II |
| CONSTRUCTION. 603.1 ALLOWABLE MATERIALS. EXCEPTION; 12. |
| STAGES AND PLATFORMS CONSTRUCTED IN ACCORDANCE WITH |
| SECTIONS 410.3 AND 410.4, RESPECTIVELY. |
| 410.4 PLATFORM CONSTRUCTION. PERMANENT PLATFORMS SHALL |
| BE CONSTRUCTED OF MATERIALS AS REQUIRED FOR THE TYPE OF |
| CONSTRUCTION OF THE BUILDING IN WHICH THE PERMANENT |
| PLATFORM IS LOCATED. PERMANENT PLATFORMS ARE PERMITTED |
| TO BE CONSTRUCTED OF FIRE-RETARDANT-TREATED WOOD FOR |
| TYPES I, II AND IV CONSTRUCTION WHERE THE PLATFORMS ARE |
| NOT MORE THAN 30 INCHES (762 MM) ABOVE THE MAIN FLOOR, |
| AND NOT MORE THAN ONE-THIRD OF THE ROOM FLOOR AREA AND |
| NOT MORE THAN 3,000 SQUARE FEET (279 M2) IN AREA. WHERE |
| THE SPACE BENEATH THE PERMANENT PLATFORM IS USED FOR |
| STORAGE OR ANY PURPOSE OTHER THAN EQUIPMENT, WIRING OR |
| PLUMBING, THE FLOOR ASSEMBLY SHALL BE NOT LESS THAN |
| 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION. WHERE THE |
| SPACE BENEATH THE PERMANENT PLATFORM IS USED ONLY FOR |
| EQUIPMENT, WIRING OR PLUMBING, THE UNDERSIDE OF THE |
| PERMANENT PLATFORM NEED NOT BE PROTECTED. |
| |
| 21F) THE S-13 SHEET DOES NOT PROVIDE THE TYPE OF |
| ANCHORS TO HOLD THE LEDGER BOARD NOR THE TYPE OF |
| BUCKETS TO HOLD THE FRAMING MEMBERS. 107.3.5 MINIMUM |
| PLAN REVIEW CRITERIA FOR BUILDINGS. 107.3.5.1 |
| COMMERCIAL BUILDINGS. FLOOR SYSTEMS. |
| |
| 21G) POOLS AND ASSOCIATED EQUIPMENT WILL BE UNDER |
| SEPARATE PERMITS FOR EACH UNIT FOR THE RECORDING OF |
| INSPECTIONS. 105.1. PERMITS REQUIRED. |
| |
| 22) SHEET A3.03 THE GREEN SCREEN SYSTEM PANELS CAN BE A |
| SUBMITTAL THAT COULD QUALIFY AS A DEFERRED SUBMITTAL, |
| PLEASE PROVIDE THE WIND DESIGN PARAMETERS FOR THE |
| SPECIALTY ENGINEERS CAN DESIGN TO THE PROPER WIND |
| SPEED. 107.3.4.2 DEFERRED SUBMITTALS. 2014 FBC-B |
| 1603.1.4 WIND DESIGN DATA. |
| |
| 23) SHEET A2.05 ROOF PLAN. |
| |
| 23A) THE ROOF DRAINS 2 & 3 BOTH ARE MISSING |
| SECONDARY(EMERGENCY OVERFLOW) DRAINS OR SCUPPERS. FBC-B |
| 1503.4.1. |
| |
| 23B) STAIR TOWER 1 & 2 BOTH SHOW OVERFLOW SCUPPERS BUT |
| NO SECONDARY (EMERGENCY OVERFLOW) DRAINS OR SCUPPERS. |
| FBC-B 1503.4.1. |
| |
| 23C) PLEASE PROVIDE DETAILS FOR SCUPPERS AND OVERFLOW |
| SCUPPERS, THE BOTTOM OF EACH UNIT IN RELATIONSHIP WITH |
| THE ROOF. FBC-B 1503.4.2 SCUPPERS. OVERFLOW SCUPPERS |
| ARE SHOWN. |
| |
| 23D) PLEASE PROVIDE A ANCHORING DETAIL FOR THE ROOF TOP |
| A/C STANDS FOR THE APPROPRIATE SIZE OF ROOF TOP |
| COMPRESSOR. PLEASE ALSO INCLUDE THE ATTACHMENT OF THE |
| COMPRESSOR TO THE STAND. FBC-B 2014 FBC-B 1604.4 |
| ANALYSIS. LOAD EFFECTS ON STRUCTURAL MEMBERS AND THEIR |
| CONNECTIONS SHALL BE DETERMINED BY METHODS OF |
| STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT EQUILIBRIUM, |
| GENERAL STABILITY, GEOMETRIC COMPATIBILITY AND BOTH |
| SHORT- AND LONG-TERM MATERIAL PROPERTIES. EVERY |
| STRUCTURE SHALL BE DESIGNED TO RESIST THE OVERTURNING |
| EFFECTS CAUSED BY THE LATERAL FORCES SPECIFIED IN THIS |
| CHAPTER. SEE SECTION 1609 FOR WIND LOADS? |
| |
| 23E) PLEASE PROVIDE THE MINIMUM HEIGHT REQUIREMENTS FOR |
| THE A/C STANDS IN COMPLIANCE WITH FBC-B TABLE 1509.6.5. |
| |
| 23F) ROOFTOP SKYLIGHTS. SECTION 603 COMBUSTIBLE |
| MATERIAL IN TYPE I AND II CONSTRUCTION. 603.1 ALLOWABLE |
| MATERIALS. 15. LIGHT-TRANSMITTING PLASTICS AS PERMITTED |
| BY CHAPTER |
| 26. PLEASE PROVIDE COMPLIANCE WITH: 2609.4 AREA |
| LIMITATIONS. ROOF PANELS SHALL BE LIMITED IN AREA AND |
| THE AGGREGATE AREA OF PANELS SHALL BE LIMITED BY A |
| PERCENTAGE OF THE FLOOR AREA OF THE ROOM OR SPACE |
| SHELTERED IN ACCORDANCE WITH TABLE 2609.4. CC1 OR CC2? |
| |
| 23G) SHEET A4.03 SHOWS A CUT SECTION THROUGH THE |
| SKYLIGHT WITH A CMU CURB. THERE ARE NO DETAILS OF THIS |
| CURB IN THE ARCHITECTURAL SHEETS NOR THE STRUCTURAL |
| SHEETS. 107.2.1.3 ADDITIONAL INFORMATION IS ENQUIRED. |
| |
| 23H) PLEASE REVIEW NOTES ON THE RIGHT SIDE OF THE PAGE |
| 1-15 THESE DEAL WITH THE FLOORS BELOW. NEED TO BE |
| DELETED. 107.2.1.3 DISCREPANCY IN PLANS. |
| |
| 24) SHEET A6.03, ELEVATOR, PLEASE SHOW COMPLIANCE WITH |
| FBC-B 3002.4 ELEVATOR CAR TO ACCOMMODATE AMBULANCE |
| STRETCHER. THE ELEVATOR CAR SHALL BE OF SUCH A SIZE AND |
| ARRANGEMENT TO ACCOMMODATE AN AMBULANCE STRETCHER 24 |
| INCHES BY 76 INCHES (610 MM BY 2134 MM) WITH NOT LESS |
| THAN 5-INCH RADIUS CORNERS, IN THE HORIZONTAL, OPEN |
| POSITION AND SHALL BE IDENTIFIED BY THE INTERNATIONAL |
| SYMBOL FOR EMERGENCY MEDICAL SERVICES (STAR OF LIFE). |
| |
| DO NOT QOUTE CODE. 107.2.1 INFORMATION ON CONSTRUCTION |
| DOCUMENTS. SUCH INFORMATION SHALL BE SPECIFIC, AND THE |
| TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE OR IN |
| PART,? |
| |
| 25) SHEET A4.03 PLEASE PROVIDE DETAILS FOR THE EYEBROW, |
| ANCHORING AND TYPE OF MATERIALS CONSTRUCTED AT |
| ELEVATION 71.416 FT. 1406.2.1 TYPE I, II, III AND IV |
| CONSTRUCTION. ON BUILDINGS OF TYPE I, II, III AND IV |
| CONSTRUCTION, EXTERIOR WALL COVERINGS SHALL BE |
| PERMITTED TO BE CONSTRUCTED OF COMBUSTIBLE MATERIALS, |
| COMPLYING WITH THE FOLLOWING LIMITATIONS: 2. |
| COMBUSTIBLE EXTERIOR WALL COVERINGS SHALL BE LIMITED TO |
| 40 FEET (12 192 MM) IN HEIGHT ABOVE GRADE PLANE. |
| |
| 26) SHEET A8.11: DETAILS SHOULD BE TO THE 2014 FLORIDA |
| ACCESSIBILITY CODE NOT THE ADA. |
| |
| 26A) THE TOWEL BAR IS INDICATED TO BE 54 INCHES HIGH |
| (ADA). MUST BE IN THE REACH RANGES FOR ACCESSIBILITY. |
| SEE ACCESS. CODE 308.2.1 UNOBSTRUCTED FORWARD. 308.3.2 |
| OBSTRUCTED SIDE REACH. |
| |
| 26B) ALL OF THE DETAILS FOR GRAB BARS ARE TAKEN AT THE |
| CENTERLINE. PLEASE BE AWARE OF THE 2014 |
| FBC-ACCESSIBILITY CODE 609.4 THE MEASUREMENTS ARE TO BE |
| TAKEN FROM FINISH FLOOR TO THE TOP OF THE GRASPABLE |
| SURFACE 33-36 INCHES. |
| |
| 26C) HIGH/ LOW DRINKING FOUNTAIN. 602.4 SPOUT HEIGHT. |
| SPOUT OUTLETS SHALL BE 36 INCHES (915 MM) MAXIMUM ABOVE |
| THE FINISH FLOOR OR GROUND. 602.7 DRINKING FOUNTAINS |
| FOR STANDING PERSONS. |
| |
| SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING |
| PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 |
| INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR |
| GROUND. |
| |
| 27) SHEETS S-16 THROUGH S-19 INDICATE POSITIVE AND |
| NEGATIVE PRESSURES FOR THE COMPONENTS AND CLADDING. THE |
| PLANS DO NOT PROVIDE THE WIND DESIGN CRITERIA NOR DOES |
| THE PLANS INDICATE IF THE PRESSURES ARE IN VULT OR |
| VASD. |
| 2014 FBC-B 1603.1.4 WIND DESIGN DATA. >60 FT. TALL/ |
| ASCE 7-10. |
| THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE |
| STRUCTURE: |
| 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), |
| MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, |
| VASD, AS DETERMINED IN ACCORDANCE WITH SECTION |
| 1609.3.1. |
| 2. RISK CATEGORY. |
| 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE |
| THAN ONE WIND EXPOSURE IS UTILIZED. |
| 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. |
| 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR |
| COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY |
| DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL |
| RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ |
| M2). |
| TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| BUILDING. |
| 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. |
| |
| 28) PLEASE PROVIDE WHERE ON THE STRUCTURAL SHEETS THE |
| PRESSURES FOR ROOF ZONES 1, 2 & 3. MISSING IN THE |
| PLANS. 2014 FBC-B 1603.1.4 WIND DESIGN DATA. >60 FT. |
| TALL/ ASCE 7-10. |
| |
| 29) FOR THE PRODUCT APPROVALS WITH GLAZED OPENINGS AND |
| MULLIONS , PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, |
| TYPE OF GLAZING, MULLION INFORMATION IF REQUIRED, |
| ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING |
| SIZE THE SUBMITTED PRODUCT APPROVALS THERE ARE TO MANY |
| VARIABLE, CIRCLE TO IDENTIFY EACH COMPONENT. COMPONENTS |
| & CLADDING. |
| |
| 30) THE NOA 15-0731.06 MIAMI ROLLING DOOR SUBMITTED |
| REPORT GOOD FOR +/- 65 SHEET S-18 SHOWS PRESSURES OF |
| -87, VASD OR VULT NOT GIVEN ON THE SHEET. ALL PRODUCT |
| APPROVALS ARE IN VASD. 1609.3.1 WIND SPEED CONVERSION |
| VULT TO VASD. |
| |
| 31) .(2) ROOFING APPROVALS WERE SUBMITTED FOR THIS |
| REVIEW. |
| CARLISLE MIRASEAL FLUID APPLIED WATERPROOFING MEMBRANE |
| NOA 13-0129.22 |
| CARLISLE CCW-500-R HOT APPLIED LIQUID MEMBRANE NOA |
| 12-0801.01 |
| IN BOTH APPROVALS THERE ARE MULTIPLE SUB-SYSTEMS AND |
| ASSOCIATED PRESSURES. IN NEITHER REPORT WAS A |
| SUB-SYSTEM AND ASSOCIATED PRESSURES INDICATED. ALSO IN |
| BOTH REPORTS LIMITATION # 9 IS INDICATED NO ENHAANCED |
| FASTENING CAN OCCUR. THE PLANS DO NOT INDICATE ROOF TOP |
| PRESSURES FOR ZONES 1,2 & 3. PLEASE PROVIDE PRESSURES |
| IN VASD SINCE THE PRODUCT APPROVALS ARE IN VASD. 2014 |
| FBC- B 1603.1.4 WIND DESIGN DATA. |
| |
| 32) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| 1609.6.4.4.1 COMPONENTS & CLADDING |
| |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS. |
| (B) WINDOWS |
| (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| LOUVERS, EFIS SYSTEMS, |
| (D) ROOFING PRODUCTS AND ASSEMBLIES |
| (F) SKYLIGHTS |
| (G) PRE-ENGINEERED A/C STANDS |
| |
| 33) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 34) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |