Plan Review Notes
Plan Review Notes For Permit 16070628
Permit Number 16070628
Review Stop B
Sequence Number 2
Notes
Date Text
2016-11-18 11:27:19BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16070628
 ADD: 2223 PALM BEACH LAKES BLVD.
 CONT: BRETT DROUIN
 TEL: 561-745-6785
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 ACTION: DENIED
  
 NOTE THAT A RESPONSE LETTER WAS NOT SUBMITTED AS
 REQUESTED. A LIST OF SHEETS REVISED WAS PROVIDED, BUT
 NO EXPLANATION AS TO HOW THESE ITEMS WERE ADDRESSED. IT
 IS RECOMMENDED THAT APPLICANT CONFIRM THAT ALL COMMENTS
 HAVE BEEN ADDRESSED PRIOR TO SUBMITTAL.
  
 COMMENTS FROM PREVIOUS LIST:
  
 1) SHEET A-1 CODE SUMMARY, OCCUPANCY GROUP LISTS THIS
 OCCUPANCY TYPE AS A BUSINESS OCCUPANCY. PLEASE SEE THE
 2014 FBC-B 303.4 ASSEMBLY GROUP A-3 GYMNASIUMS (WITHOUT
 SPECTATOR SEATING).
  
 2ND REVIEW, A1 STATES THIS IS BUSINESS (SAME BOX AS
 WIND DESIGN CRITERIA).
  
 2) THE DESIGNER OF RECORD INDICATES THIS IS A LEVEL II
 ALTERATION. PLEASE PROVIDE WHERE THESE LAST KNOWN USES
 OCCUPIED WHICH PORTION OF THE BUILDING TO DETERMINE IF
 THERE IS A CHANGE OF OCCUPANCY FOR THE LOCATION OF THE
 GYMNASIUM.
 2A) ALAN WELLS COMMERCIAL REAL ESTATE/ BUSINESS TAX
 LICENSE ACTIVE UNTIL 9/30/2016
 2B) WEST PALM BEACH EVENT HALL # 1/ / BUSINESS TAX
 LICENSE ACTIVE UNTIL 9/30/2016
  
 DEPENDING ON THE LOCATION THERE MAY BE A CHANGE OF
 OCCUPANCY. AT LEAST THERE IS A CHANGE OF USE WITHIN THE
 SAME OCCUPANCY TYPE.
 2014 FBC-B 1012.1. THE PROVISIONS OF THIS SECTION SHALL
 APPLY TO BUILDINGS OR PORTIONS THEREOF UNDERGOING A
 CHANGE OF OCCUPANCY CLASSIFICATION. THIS INCLUDES A
 CHANGE OF OCCUPANCY CLASSIFICATION WITHIN A GROUP AS
 WELL AS A CHANGE OF OCCUPANCY CLASSIFICATION FROM ONE
 GROUP TO A DIFFERENT GROUP. SUCH BUILDINGS SHALL ALSO
 COMPLY WITH SECTIONS 1002 THROUGH 1011. THE APPLICATION
 OF REQUIREMENTS FOR THE CHANGE OF OCCUPANCY SHALL BE AS
 SET FORTH IN SECTIONS 1012.1.1 THROUGH 1012.1.4.
  
 2ND REVIEW, NOT ADDRESSED. THE REQUESTED INFORMATION
 WAS NOT PROVIDED. THE OUTLINE OF THE BUILDING WITH AN
 AREA HIGHLIGHTED WAS PROVIDED. IT DOES NOT PROVIDE THE
 INFORMATION REQUESTED: ALAN WELLS, EVENT HALL
 LOCATIONS, WHAT WAS IN THIS SPACE BEFORE IF IT WAS
 NEITHER OF THESE? IT IS LIKELY THAT THIS IS A CHANGE OF
 OCCUPANCY, SO THE PREVIOUS LEGAL USE SHOULD BE
 DETERMINED, PLANS REVISED TO INCLUDE THIS INFORMATION,
 AS WELL AS SHOW COMPLIANCE WITH CHANGE OF OCCUPANCY, IF
 APPLICABLE.
  
 3, 4, 5) OK
  
 6) IN THE CARDIO AREA THERE SEEMS TO BE NO AREA FOR AN
 ACCESS AISLE. PLEASE SHOW COMPLIANCE WITH 2014 FBC-B
 1028.9.2 AISLE WIDTH. THE AISLE WIDTH SHALL PROVIDE
 SUFFICIENT EGRESS CAPACITY FOR THE NUMBER OF PERSONS
 ACCOMMODATED BY THE CATCHMENT AREA SERVED BY THE AISLE.
 THE CATCHMENT AREA SERVED BY AN AISLE IS THAT PORTION
 OF THE TOTAL SPACE THAT IS SERVED BY THAT SECTION OF
 THE AISLE. IN ESTABLISHING CATCHMENT AREAS, THE
 ASSUMPTION SHALL BE MADE THAT THERE IS A BALANCED USE
 OF ALL MEANS OF EGRESS, WITH THE NUMBER OF PERSONS IN
 PROPORTION TO EGRESS CAPACITY.
  
 2ND REVIEW, IT IS NOT CLEAR HOW THIS HAS BEEN
 ADDRESSED. THE EQUIPMENT PLAN SHOWS EQUIPMENT DENSELY
 LOCATED, WITH LITTLE ROOM PROVIDED FOR OCCUPANT EGRESS.
 REVISE PLAN TO SHOW THE CLEAR WIDTH OF AREAS FOR
 EGRESS. ALSO, THE LACK OF SPACE BETWEEN EQUIPMENT
 APPEARS TO SHOW LACK OF COMPLIANCE WITH FBC
 ACCESSIBILITY 236, 1004.
  
 7) OK
  
 8) OK
  
 9) OK WITH PROVISO; IF MECHANICAL REVIEW DETERMINES
 THAT NEW EQUIPMENT IS REQUIRED, PROVIDE ANCHORING,
 STAND OR CURB DETAILS.
  
 10) THE PLANS NEED TO GO TO PALM BEACH COUNTY IMPACT
 FEE OFFICE FOR REVIEW. BEFORE A PERMIT TO CONSTRUCT,
 MAY BE ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY. THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED
 BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED
 TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025
 FOR MORE INFORMATION.
  
 THIS MAY BE DONE AFTER ALL PLAN REVIEWS HAVE PASSED,
 BUT BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 NEW COMMENTS:
  
 12. SEE NFIP REVIEW. AS DESIGN TO RESIST FLOOD LOADS IS
 A REQUIREMENT OF THE BUILDING CODE (FBC B 1612), REVISE
 THE PLAN TO SHOW COMPLIANCE. OPTIONS WERE SENT VIA
 EMAIL TO OWNER'S REP ON 10/13/16. APPLICANT MAY SEND
 INFORMATION FOR PRELIMINARY REVIEW (SUCH AS ELEVATION
 CERTIFICATE, APPRAISAL) VIA EMAIL PRIOR TO
 RESUBMITTING.
  
 13. EXERCISE MACHINES AND EQUIPMENT ARE TO COMPLY WITH
 FBC ACCESSIBILITY 236, 1004. REVISE PLAN TO SHOW
 COMPLIANCE. NOTE THAT THIS WOULD HAVE BEEN A PROVISO
 ITEM HAD ALL OTHER BUILDING COMMENTS BEEN ADDRESSED.
 HOWEVER, SINCE THE PLANS NEED TO BE REVISED TO ADDRESS
 OTHER COMMENTS FOR BOTH BUILDING AND OTHER TRADES,
 REVISE TO SHOW COMPLIANCE AT THIS TIME.
  
 14. IF IT IS DETERMINED THAT THIS PROJECT INCLUDES A
 CHANGE OF OCCUPANCY, PLAN SHOULD BE REVISED TO SHOW
 COMPLIANCE WITH FBC EXISTING BUILDING CHAPTER 10. A
 COMPLETE LIST CANNOT BE PROVIDED DUE TO LACK OF
 INFORMATION. FOR INSTANCE, SEE FBC EXISTING BUILDING
 TABLE 1012.4. IF THIS WAS BUSINESS, AND ASSEMBLY IS
 PROPOSED, THE MEANS OF EGRESS SHALL COMPLY WITH FBC
 CHAPTER 10 AS ASSEMBLY IS A HIGHER CATEGORY. IN THAT
 CASE, PANIC OR FIRE EXIT HARDWARE IS REQUIRED FOR ALL
 DOORS IN THE MEANS OF EGRESS. EXTERIOR DOORS, IF THEY
 DO NOT INCLUDE PANIC DEVICES, WOULD BE REQUIRED TO BE
 REPLACED.
  
 THIS LIST CANNOT BE COMPLETE AS IT IS NOT POSSIBLE TO
 DO A COMPLETE REVIEW WITHOUT FIRST DETERMINING THE
 PREVIOUS LEGAL OCCUPANCY.
  
 15. SEE FLORIDA STATUTE 553.80 (2) (B), AND NOTE IN
 PARTICULAR THE LANGUAGE "SHALL" (RATHER THAN "MAY"):
  
 (B) WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS'
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
 SAMANTHA HILL (FOR JIM WITMER)
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6724, FAX: 561-805-6676
 E-MAIL: [email protected]
  
  