2017-02-22 08:53:102ND REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS: 2ND REQUEST PREVIOUS COMMENTS NOT
 ADDRESSED.
  
 1. SHOW LAUNDRY ON RISER DIAGRAM IT SHALL CONNECT TO
 BUILDING DRAIN DOWN STREAM OF BATHROOM GROUP. WPB AMEND
 TO FBC 107.3.5.3(11) / FBC RES P3108.4
 2. SHOW LOCATION OF WATER HEATER. PER WPB AMEND TO FBC
 107.2.1
  
 NEW COMMENTS;
  
 1. REVISE DESCRIPTION OF WORK ON THE PLUMBING SUB
 PERMIT APPLICATION TO REFLECT THE COMPLETE SCOPE OF
 WORK SHOWN ON THE PLAN. PER WPB AMEND TO FBC 107.2.1
  
 2. PROVIDE DIMENSION OF THE NEW SHOWER SHALL COMPLY
 WITH FBC RES P2708.1 GENERAL.
 SHOWER COMPARTMENTS SHALL HAVE NOT LESS THAN 900 SQUARE
 INCHES (0.6 M2) OF INTERIOR CROSS-SECTIONAL AREA.
 SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 30 INCHES
 (762 MM) IN MINIMUM DIMENSION MEASURED FROM THE
 FINISHED INTERIOR DIMENSION OF THE SHOWER COMPARTMENT,
 EXCLUSIVE OF FIXTURE VALVES, SHOWER HEADS, SOAP DISHES,
 AND SAFETY GRAB BARS OR RAILS. THE MINIMUM REQUIRED
 AREA AND DIMENSION SHALL BE MEASURED FROM THE FINISHED
 INTERIOR DIMENSION AT A HEIGHT EQUAL TO THE TOP OF THE
 THRESHOLD AND AT A POINT TANGENT TO ITS CENTERLINE AND
 SHALL BE CONTINUED TO A HEIGHT OF NOT LESS THAN 70
 INCHES (1778 MM) ABOVE THE SHOWER DRAIN OUTLET. HINGED
 SHOWER DOORS SHALL OPEN OUTWARD. THE WALL AREA ABOVE
 BUILT-IN TUBS HAVING INSTALLED SHOWER HEADS AND IN
 SHOWER COMPARTMENTS SHALL BE CONSTRUCTED IN ACCORDANCE
 WITH SECTION R702.4. SUCH WALLS SHALL FORM A
 WATER-TIGHT JOINT WITH EACH OTHER AND WITH EITHER THE
 TUB, RECEPTOR OR SHOWER FLOOR.
  
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  