2016-09-02 12:03:46 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 16070370 |
| ADD: 6021 S. DIXIE HWY. |
| CONT: SISCA CONSTRUCTION |
| TEL: 561-228-7503 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: FRI. SEPT. 02/ 2016 |
| |
| ACTION: BUILDING PROVISO |
| BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES |
| |
| 1) THE ROOF TOP A/C STAND PRODUCT APPROVAL A MIAMI-DADE |
| NOA # 1301017.09 WAS SUBMITTED, REVIEWED BY THE |
| DESIGNER OF RECORD. NEITHER THE CONTRACTOR NOR THE |
| DESIGNER OF RECORD HAVE FOLLOWED THE PRODUCT APPROVAL |
| IN CALCULATING THE AREA OF THE ROOF TOP COMPRESSORS, |
| THE MEAN ROOF HEIGHT OF THE STAND AND COMPRESSORS, |
| WEIGHT, CIRCLED THE DESIGN PARAMETERS IN THE TABLES , |
| ANCHORS AND UPLIFT VERSES MOMENT. THE TITLE SHEET SHOWS |
| DETAIL A/ T000, THIS CONNECTION ONLY SHOWS THE CORNERS |
| OF THE A/C CONDENSER CLIPPED TO THE STAND. NO MENTION |
| OF WHAT THE 4 ANCHORS ARE NOR THE TYPE OF CLIP |
| MATERIAL, SIZE, NOR THICKNESS OF THE CLIP. |
| |
| 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL |
| MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY |
| METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT |
| EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY |
| AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. |
| EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE |
| OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES |
| SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND |
| LOADS? |
| |
| 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL |
| EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO |
| WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND |
| PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND PRESSURE |
| FOR EACH COMPONENT OR CLADDING ELEMENT IS TO BE |
| DESIGNED FOR WIND PRESSURES COMPONENTS AND ATTACHMENTS. |
| |