2016-09-02 12:03:46BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16070370
 ADD: 6021 S. DIXIE HWY.
 CONT: SISCA CONSTRUCTION
 TEL: 561-228-7503
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: FRI. SEPT. 02/ 2016
  
 ACTION: BUILDING PROVISO
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES
  
 1) THE ROOF TOP A/C STAND PRODUCT APPROVAL A MIAMI-DADE
 NOA # 1301017.09 WAS SUBMITTED, REVIEWED BY THE
 DESIGNER OF RECORD. NEITHER THE CONTRACTOR NOR THE
 DESIGNER OF RECORD HAVE FOLLOWED THE PRODUCT APPROVAL
 IN CALCULATING THE AREA OF THE ROOF TOP COMPRESSORS,
 THE MEAN ROOF HEIGHT OF THE STAND AND COMPRESSORS,
 WEIGHT, CIRCLED THE DESIGN PARAMETERS IN THE TABLES ,
 ANCHORS AND UPLIFT VERSES MOMENT. THE TITLE SHEET SHOWS
 DETAIL A/ T000, THIS CONNECTION ONLY SHOWS THE CORNERS
 OF THE A/C CONDENSER CLIPPED TO THE STAND. NO MENTION
 OF WHAT THE 4 ANCHORS ARE NOR THE TYPE OF CLIP
 MATERIAL, SIZE, NOR THICKNESS OF THE CLIP.
  
 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL
 MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY
 METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT
 EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY
 AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES.
 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS?
  
 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL
 EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO
 WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND
 PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA
 BUILDING CODE, BUILDING.
  
 B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND PRESSURE
 FOR EACH COMPONENT OR CLADDING ELEMENT IS TO BE
 DESIGNED FOR WIND PRESSURES COMPONENTS AND ATTACHMENTS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  