Plan Review Notes For Permit 16070314 |
Permit Number |
16070314 |
|
Review Stop |
FIRE |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2016-07-21 08:15:32 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | 1) THE ROOF DESIGN IS SUCH THAT A LIGHTWIEIGHT ROOF | | TRUSS IS REQUIRED PER FLORIDA 69A-60.0081; NOTICE | | SIGNAGE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME | | TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR | | ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR | | MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | MARKED WITH THE LETTER "R". | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | SHALL BE MARKED WITH THE LETTER "F". | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|